Maintaining the SMS 100 and AMS 2100/2300 Arrays

This help page provides information to guide you through the basic maintenance operations available in Navigator 2 for SMS users.  It contains the following topics:

Installing Spare Drives

To install a spare drive:

  1. Wear an anti-static wristband connected to the array frame.

  2. Remove the front bezel to access to drives.

  3. Open the door to a vacant spare drive slot.

  4. Locate the drive slot into which you will install the drive. Viewed from the front of the array, there is pone spare drive slot at the left end of the row of drives, and another one at the right end.

  5. Remove the new drive from its anti-static bag and slide it into one of the spare drive slots until the locking handle engages. When the drive is installed, it begins to spin up automatically.

  6. Be sure the drive is installed securely in the slot.

  7. Close the door to the drive slot.

  8. To install a second spare drive, repeat steps 3 through 7 with a second drive and the second drive slot.

  9. Replace the front bezel.

  10. In the Failed Part List, click the Scan for Errors button.

  11. Verify that the Failed Part List shows No Object, which indicates that there are no failed drives or other devices in the Hitachi Simple Modular Storage

  12. Remove the anti-static wristband.

For further information, see Chapter 4, Maintaining Your System in the Simple Modular Storage 100 System User's Guide,

Replacing an Entire Array  

 

See Also   (back to top)