Managing iSCSI Targets

This help page provides information about iSCSI Targets and how and when to use them.  It contains the following topics:

Overview

An iSCSI target is a logical entity that associates one or more hosts that communicate with the array via the iSCSI protocol and one or more logical units in an array.

Think of it as a logical "box" within an array.  The box contains one or more LUNs and one or more iSCSI ports. The iSCSI ports connect the target to one or more hosts. When a host "sees" the iSCSI port, it also sees the iSCSI target containing the LUNs.  The host can then access any or all of LUNs and the data they contain.

Host access is for managing data only.  Hosts cannot manage the LUNs themselves (for example, add, delete, modify, and so forth) , nor the iSCSI targets that contain them.  Those functions are handled by Navigator 2, which is installed on a management console.  See the following illustration.

Multiple Host Connections

One host can connect to an iSCSI port on the array without setting security (see Host 2 in the above illustration).  To connect more than one host to an iSCSI target, you must first enable iSCSI target security (see Host 1 and Host 2 in the above illustration). This is also true if one host connects to more than one iSCSI target (see Host 3 in the above illustration).  The security uses CHAP (Challenge Handshake Access Protocol), which requires that the host that is trying to connect to the iSCSI port "knows" the CHAP secret that is set for the port.  This is similar to logging in with a password.  CHAP security setup information is included in this help topic.

Multipathing

Multipathing means that a host is connected to an iSCSI target via more than one port. See the above illustration.

Displaying iSCSI Targets

You can refer/ configure groups (logical resources) in the array:

  1. In the Arrays window, select the array you want to manage and click Show and Configure Array.  The Array window and Explorer tree are displayed..

  2. In the Explorer tree, click Groups. The Groups window is displayed.

  3. In the Groups window, click iSCSI Target in the list of Groups. 

Note: iSCSI Targets is not displayed if the Array does not have iSCSI interface to communicate with hosts.

The iSCSI Targets Tab

This tab has the list of the iSCSI targets in the array.

 

iSCSI Target

The number and name of the iSCSI target.

Port

Through this iSCSI port, the iSCSI target communicates with hosts and/or other arrays.

Platform

Configuration of platform of the iSCSI target

High Availability

Configuration of middleware of the iSCSI target

Auth Method

Configuration of authentication of the iSCSI target. There are 3 cases.

None: The hosts must access to the iSCSI target without CHAP authentication.

CHAP: The hosts must access to the iSCSI target with CHAP authentication.

CHAP, None: If the host required to access to the iSCSI target with CHAP authentication, the authentication is done.  Otherwise the hosts can access to the iSCSI target without CHAP authentication..

iSCSI Name

Name of the iSCSI target informed to the hosts and iSNS.

Showing iSCSI Target Properties

To view the details of an iSCSI Target, click the name of the desired iSCSI target.

Creating a Target

NOTE: If the LUN Manager storage feature is not installed and enabled, this button is not displayed. In the Array tree, Check the Settings > Licenses dialog box to verify that the LUN Manager feature is installed and enabled.  See the Licenses help page for more information.

As shown on the tool tip, the name of this button is an abbreviation of Create iSCSI Target.

To create one or more iSCSI targets on iSCSI Port(s):

  1. In iSCSI Targets tab of iSCSI Targets window, click Create Target. The Create iSCSI Target dialog box is displayed.

  2. In the Create Target Window:enter the Number, Alias, iSCSI Name of the target.

  3. Select one or more iSCSI Ports that the iSCSI target belongs to

NOTE: The Available Ports list is a list of iSCSI Ports where iSCSI target security is enabled.

3.  The Create iSCSI Target window includes three tabs for settings: Hosts tab, Logical Units tab, and Settings tab.  These are described below.

The Hosts tab

If the LUN Manager (option program) is not installed or enabled in the array, this tab is not displayed.

Check Select from Detected Hosts and select host(s) in the Detected Hosts list (This is the list of hosts that has tried to the iSCSI Port. The iSCSI names of those hosts are recorded in the array and you need not type manually.), or check Enter iSCSI Name Manually and type iSCSI Name in the iSCSI Name field.  Then click Add to assign the host(s) to the iSCSI target.  When de-assign host(s), select hosts from Selected Hosts list and click Remove button.

The  Logical Units tab

(The following operation is called ”set LU mapping”, or ”map LU to iSCSI targets.”)

Select an H-LUN in H-LUN list, LUN(s) in Available LUs list and click Add button. In the Selected LUs list, LUN of logical unit is to be seen as H-LUN from the hosts allowed to access to the iSCSI target. Thus the logical unit in the array is mapped to H-LUN. If you remove the selected logical unit from the Selected LUs list, click the of  the logical unit in the Selected LUs list and click Remove button.

The Options tab

Select the platform and middleware of the host(s) by selecting pull-down menus to the left of Platform and Middleware.

Select the setting of host connection mode by the pull-down menu of Common Settings or es to the items of Additional Setting against host commands.

4. After finishing the settings of the iSCSI target, click OK to configure the iSCSI Target in the array.  After the creation, you can modify the settings by Edit Target button in.

Editing a Target

To edit the configuration of an iSCSI target:

  1. In the iSCSI Targets window, select the iSCSI Targets tab.

  2. In  the iSCSI Targets tab, select an iSCSI target (click the next to its name).

  3. Click Edit Target. The Edit iSCSI Target window is displayed.  The Edit iSCSI Target window includes areas which are directly editable and areas which must be edited via one of the three tabs in the lower half of the window.  Each of the tabs is explained below.

iSCSI Target Settings

Before describing how to change all the settings, let's first look at what the settings are and what they do.  The following table explains each setting and includes a link to the instructions to change the setting.

In the Edit Target Window:

  1. Enter the Number, Alias, and iSCSI Name of the target. See the

  2. Select one or more iSCSI Ports to which the iSCSI target belongs.

NOTE: The Available Ports list is a list of iSCSI Ports where iSCSI Target Security is enabled. If LUN Manager is not enabled, iSCSI ports cannot be selected from this list.

 

3. The Create iSCSI Target window includes three tabs as described below.

The Hosts Tab

NOTE: If the LUN Manager storage feature is not installed and enabled, this tab is not displayed. In the Array tree, Check the Settings > Licenses dialog box to verify that the LUN Manager feature is installed and enabled.  See the Licenses help page for more information.

The Logical Units Tab

(The following operation is called as ”set LU mapping”, or ”map LU to iSCSI targets.”)

Select an H-LUN in H-LUN list, and/or logical units in the Available Logical Units list and click Add.

 In the Selected Logical Units list, LUN of logical unit is to be seen as H-LUN from the hosts allowed to access to the iSCSI target. Thus the logical unit in the array is mapped to H-LUN. If you remove the selected logical unit from the Selected LUs list, click the of  the logical unit in the Selected LUs list and click Remove button.

The Options Tab

Select the platform and middleware of the host(s) by selecting pull-down menus to the left of Platform and Middleware.

Select the setting of host connection mode by the pull-down menu of Common Settings or es to the items of Advanced Setting.

4. After finishing the settings of the iSCSI target, click OK to configure the iSCSI Target in the array.  After the creation, you can modify the settings by Edit Target button in.

Editing  Authentication

To edit the authentication setting of an iSCSI Target:

  1. In the iSCSI Targets tab of iSCSI Targets window, click of the iSCSI Target and click Edit Authentication button. The Edit Authentication window is displayed.

NOTE: This button is the same as the Edit Authentication button in the Authentication tab of the iSCSI Target Property window.

 

In the Edit Authentication window:

  1. Select authentication method  If ”CHAP, None” or ”CHAP” is selected for Authentication Method, associate CHAP Users to the iSCSI Target later at CHAP Users tab of iSCSI Targets window.  The array can verify the user (of the host trying to access the iSCSI target) by the User Name and Secret of the CHAP user.

  2. To set enable mutual authentication or not.  If enabled, input authentication setting s for iSCSI target.  If enabled, the host can verify the iSCSI target by the User Name and Secret of the iSCSI target.

Initializing Target 000

NOTE: This button is not displayed when the LUN Manager storage feature is not installed or enabled in the array.

As shown on the tool tip, this button is abbreviation of Initialize iSCSI Target 000. Each iSCSI port has iSCSI Target 000 by default. You cannot delete iSCSI Target 000 but can initialize iSCSI Target 000.

To initialize one or more iSCSI Target 000 units on iSCSI Port(s), in iSCSI Targets  tab of iSCSI Targets window, click (es) of iSCSI Targets 000 and click Initialize Target 000 button. Initialize iSCSI Target 000 window is displayed.

Deleting a Target

If LUN Manager is not installed or enabled in the array, this button is not displayed.

As shown on the tool tip, this button is abbreviation of Delete iSCSI Target. You cannot delete iSCSI Target 000.

The iSCSI Target Security Tab

NOTE: This tab is not displayed when the LUN Manager storage feature is not installed or enabled in the array.

To create iSCSI Target on an iSCSI port:

The iSCSI Target Security tab includes a list showing the configuration of the iSCSI ports on iSCSI target security configurations..

 

ISCSI Port

iSCSI ports in the array

Enable iSCSI Target Security

Select Yes to enable security on the selected iSCSI target. With iSCSI security enabled, only one host can connect to this iSCSI target. This is the recommended setting because it prevents one host from overwriting the data and/or settings from another host.

Select No to disable security on the selected iSCSI target. WithiISCSI security disabled, multiple hosts can connect to this iSCSI target.

Changing iSCSI Target Security

Complete the following instructions to change the iSCSI target security setting of an iSCSI port. Also see the following illustration.

  1. In the iSCSI Targets window, select the iSCSI Target Security tab.

  2. In the iSCSI Security tab, click the to the left of the name of the of the iSCSI port of interest.

  3. Click Change iSCSI Target Security.  The Change iSCSI Target Security dialog box (shown over the top of the tab) is displayed.

  4. Click the to set or reset iSCSI Target Security of the selected iSCSI port

  5. Click OK to save the changes.  A confirmation dialog box is displayed.

  6. Click Close to acknowledge and close the dialog box, and return to the iSCSI Target Security tab.

The Hosts Tab

NOTE: This tab is not displayed when the LUN Manager storage feature is not installed or enabled in the array.

This tab displays the list of the hosts that are assigned to an iSCSI target or that are able to associated to an iSCSI target. The table below describes the information that is displayed for each listed host.

 

Nickname

Nickname set to the host. This is used only on the navigator.

Assigned to iSCSI Target

Whether the host is assigned to an iSCSI target of the array or not.

Port

This is the iSCSI  port through which a host communicates with the array.

ISCSI Name

This is the ISCSI name of the host

Changing a Host Nickname

NOTE: This function is disabled when the LUN Manager storage feature is not installed or enabled in the array.

To enter a new nickname for a host or edit an existing nickname:

  1. In the iSCSI window, select the Hosts tab.

  2. Select the desired host by clicking the to the left of the host name and click Change Nickname.  The Change Nickname window is displayed.

  3. In the Change Nickname window, enter a new nickname for the host or edit an existing nickname as needed. A nickname can be 1 - 32 alphanumeric characters. The nickname is used only within Navigator 2 and is not sent to the hosts or arrays.

This function is also accessible by clicking Change Nickname in the iSCSI Target Property window.

The CHAP Users Tab

This tab displays the list of the CHAP (Challenge Authentication Handshake Protocol) users of the hosts.

 

CHAP User

The user name (on hosts) allowed to access with CHAP with registered secret of the user.  CHAP users that have the same name can be registered to multiple iSCSI port.

Port

Through the iSCSI port, the CHAP user is allowed to access the array.

Showing Details

To refer the detail configuration of a CHAP user, in CHAP Users tab of iSCSI Targets window,  click the of the CHAP User that you want to look at details and click Show Details button.

Creating a  CHAP User

To register a new CHAP user, in CHAP Users tab of iSCSI Targets window, click Create CHAP User button. Create CHAP User window is displayed. Enter the User name, type Secret and retype Secret. Click one or more to the left of the Port (iSCSI Port) where you want to create the CHAP user in the Available Port list.

Notes:

To view the details of the CHAP user you create, click the of the CHAP user and click Show Details button in the CHAP User list.

Editing a CHAP User

To register a new CHAP user, select the of the CHAP User that you want to configure and click Edit CHAP User.

To change the user name of the CHAP user, overwrite the user name in User Name field.

To change secret of the CHAP user, select the to the right to Change Secret, type a new secret to Secret field and retype the new secret to Retype Secret  field.

Assign a target to the CHAP user

To view the details of the CHAP user you edit, click the of the CHAP user and click Show Details button in the CHAP User list.

Deleting a CHAP User

To delete CHAP Users, click the of the CHAP Users that you want to delete and click Delete CHAP User button.

iSCSI Target Properties

The details of the iSCSI Target are displayed in this page.

Summary Area

ISCSI Target

The number and name of the iSCSI target.

Port

Through this iSCSI port, the iSCSI target communicates with hosts and/or other arrays.

Platform

Configuration of platform of the iSCSI target

Middleware

Configuration of middleware of the iSCSI target

Editing a Target

As shown on the tool tip, this button is an abbreviation of Edit iSCSI Target.

To Edit an iSCSI Target, in upper right of iSCSI Target property window, click Edit Target button. Edit iSCSI Target window is displayed.

This button is the same as the Edit Target button in the iSCSI Target tab of iSCSI Targets window.

The Hosts tab

This tab displays the list of the hosts that are assigned to an iSCSI target or that are able to associate with an iSCSI target.

 

Nickname

Nickname set to the host. This is used only on the navigator.

ISCSI Name

ISCSI name of the host

 

If the LUN Manager (bundled storage feature) is not installed or enabled in the array, this tab is not displayed.

 

Changing a  Nickname

The function cannot executed when LUN Manager (option program) is disable.

To set a new nickname to a host or change the nickname of a host, in Hosts tab of iSCSI Target property window, select the host by clicking the tot he left of the list of hosts and click Change Nickname. Change Nickname window is displayed. Enter new nickname of the host. A nickname of a host should be 32 or less alphanumeric characters. The nickname is used only within Navigator 2 and not sent to the hosts nor arrays.

The Logical Units tab

This has the list of the logical units associated to the iSCSI target.

 

H-LUN

Logical Unit Number seen from the hosts (H-LUN) through the iSCSI target.

LUN

Logical Unit Number (LUN) of the actual logical unit in the array.

Mapping Guard

Mapping guard is a function to protect mapping against erroneous operations.  If this is enabled, you cannot map the logical unit to iSCSI Targets.

Capacity

Capacity of the logical unit.

RAID Group

RAID group number where the logical unit is defined.

RAID Level

RAID level of the RAID group where the logical unit is defined.

Drive Type

Drive type of the RAID group where the logical unit is defined.

Status

Status of the logical unit. (e.g. Normal, Formatting, etc.)

The Authentication tab

ISCSI Name of the Target

Name of the iSCSI target in the array informed to the hosts and iSNS.

Authentication Method

Configuration of authentication of the iSCSI target

CHAP Algorithm

Algorithm used for CHAP.  This is not configurable and fixed to MD5 in the array.

Mutual Authentication

If enabled, the host can test the iSCSI target by the User Name and Secret of the iSCSI target.

User Name for Mutual Authentication

User Name used for mutual authentication.  This can be defined one for one iSCSI target in Edit Authentication window.

Editing  Authentication

To edit the authentication setting of the iSCSI Target, click Edit Authentication.  The Edit Authentication window is displayed.

This button is the same as the Edit Authentication button in iSCSI Targets tab of the iSCSI Targets window.

In the Edit Authentication window:

  1. Select authentication method  If ”CHAP, None” or ”CHAP” is selected for Authentication Method, associate CHAP Users to the iSCSI Target later at CHAP Users tab of iSCSI Targets window.  The array can verify the user (of the host trying to access the iSCSI target) by the User Name and Secret of the CHAP user.

  2. To set enable mutual authentication or not.  If enable, input authentication setting s for iSCSI target.  If enabled, the host can test the iSCSI target by the User Name and Secret of the iSCSI target.

The Options tab

Common Setting

Common configuration against host commands.

Additional Settings

Additional configuration against host commands.

See Also   (back to top)

The following topics within this online help provide information that may be helpful in understanding the information on this page, and/or may provide additional information that is related, but not required to understand this topic.

   Settings

   Managing RAID Groups