--- ./source/private_module/cls/cls_power_lost.c	2018-04-04 09:03:55.000000000 +0000
+++ ./source/private_module/cls/cls_power_lost.c.hotpatch	2021-12-10 03:57:13.000000000 +0000
@@ -2474,7 +2474,7 @@
 
     /*ӴӡϢ*/
     powerLostTask = (POWER_LOST_TASK_S*)task;
-
+    DBG_LogInfo(DBG_LOGID_NEW, "CLS_POWER_LOST: No need stop bdm io when high tempture.");
     /*, BDMֹ֮ͣIO, DBACTIONҪ*/
     if ((B_FALSE == getNodeACFlag()) && (0 != getIsolateFlag()))
     {
@@ -3169,7 +3169,7 @@
     SET_TASK_ACTION(task, idx, ACTION_NODE_CLOSE_PWR);
     idx++;
     SET_TASK_ACTION(task, idx, ACTION_OPCODE_BUTT);
-
+    DBG_LogInfo(DBG_LOGID_NEW, "CLS_POWER_LOST: No need delay stop ccdb when power lost.");
     return;
 }
 