WEBVTT

1
00:00.220 --> 00:01.053
So, in this video,

2
00:01.053 --> 00:02.720
I'd like to walk through creating a pool

3
00:02.720 --> 00:04.120
of addresses that can be used

4
00:04.120 --> 00:06.260
if we're using VLAN 101,

5
00:06.260 --> 00:07.420
and other pool of addresses

6
00:07.420 --> 00:09.070
that we can use for tunnel endpoints

7
00:09.070 --> 00:12.797
if we're using the network 10.22.22, and VLAN 102.

8
00:12.797 --> 00:15.100
And then once we've created those pools of addresses

9
00:15.100 --> 00:16.480
that can be used,

10
00:16.480 --> 00:17.680
we'll also walk through the creation

11
00:17.680 --> 00:18.990
of some uplink profiles.

12
00:18.990 --> 00:20.429
We simply say,

13
00:20.429 --> 00:21.890
hey, which VLAN do we want to use

14
00:21.890 --> 00:23.880
for the transport network?

15
00:23.880 --> 00:25.970
And which uplinks do we want to go ahead

16
00:25.970 --> 00:28.030
and use on the ESXi hosts?

17
00:28.030 --> 00:30.550
So, to do this, we're going to log into the NSX Manager,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

17
00:28.030 --> 00:30.550
So, to do this, we're going to log into the NSX Manager,

18
00:30.550 --> 00:32.079
and we're going to use the virtual IP address

19
00:32.079 --> 00:33.390
that we set up,

20
00:33.390 --> 00:34.799
which is at .10 on the management network.

21
00:34.799 --> 00:37.600
So, I'll log in as admin, supply the password,

22
00:37.600 --> 00:39.080
and click log in.

23
00:39.080 --> 00:41.803
Also, one of the other things I definitely want to do

24
00:41.803 --> 00:42.800
before we get too far along is

25
00:42.800 --> 00:44.620
I want to make sure that this VM,

26
00:44.620 --> 00:46.460
this NSX Manager VM,

27
00:46.460 --> 00:48.840
is set to automatically power up

28
00:48.840 --> 00:50.870
when my ESXi host comes up.

29
00:50.870 --> 00:52.489
So, let's go back to the vSphere client just

30
00:52.489 --> 00:53.739
for a moment.

31
00:53.739 --> 00:54.400
And here at the vSphere client,

32
00:54.400 --> 00:56.470
go back to the host and clusters view.

33
00:56.470 --> 00:58.780
We'll go to our management cluster.

34
00:58.780 --> 01:02.320
We'll go to ESXIC, and we'll go to configure.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

34
00:58.780 --> 01:02.320
We'll go to ESXIC, and we'll go to configure.

35
01:02.320 --> 01:03.500
Then in this middle column,

36
01:03.500 --> 01:06.740
we'll go down to VM startup shutdown.

37
01:06.740 --> 01:08.320
And currently, this is showing with this tab,

38
01:08.320 --> 01:10.260
the automatic ordered and automatic.

39
01:10.260 --> 01:14.750
Yeah, this little NSX Manager VM is not set for any kind

40
01:14.750 --> 01:15.940
of automatic startup.

41
01:15.940 --> 01:18.440
So currently, it's set up for manual startup,

42
01:18.440 --> 01:20.723
which means it's not going to automatically power on

43
01:20.723 --> 01:22.870
if I have to reboot the NSX host

44
01:22.870 --> 01:24.019
for any reason.

45
01:24.019 --> 01:26.450
So, to solve that, I'm going to click on edit.

46
01:26.450 --> 01:27.750
And I'm going to go ahead and click here

47
01:27.750 --> 01:31.560
on manual startup and select the NSX Manager VM,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

47
01:27.750 --> 01:31.560
on manual startup and select the NSX Manager VM,

48
01:31.560 --> 01:34.420
where the automatic startup is currently disabled.

49
01:34.420 --> 01:36.830
And I'm going to go ahead and click here on move to.

50
01:36.830 --> 01:40.090
And I want to move this to the automatic ordered.

51
01:40.090 --> 01:41.440
So, it's removed from this list now.

52
01:41.440 --> 01:43.270
Now it's under the automatic order

53
01:43.270 --> 01:45.549
and it's in startup order number one.

54
01:45.549 --> 01:46.909
Fantastic.

55
01:46.909 --> 01:48.480
So, I want to make that change before we go any further

56
01:48.480 --> 01:50.230
because it can take like 10 to 15 minutes

57
01:50.230 --> 01:51.930
for this little VM to fully initialize.

58
01:51.930 --> 01:54.600
And so, if it automatically is going to start it every time

59
01:54.600 --> 01:56.430
the host is rebooted,

60
01:56.430 --> 01:57.590
it's going to save me some frustration later.

61
01:57.590 --> 02:00.130
So, with that set, I'll click on OK.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

61
01:57.590 --> 02:00.130
So, with that set, I'll click on OK.

62
02:00.130 --> 02:01.340
And then just to verify here,

63
02:01.340 --> 02:02.830
if we click on the automatic ordered,

64
02:02.830 --> 02:04.010
it's showing up right there.

65
02:04.010 --> 02:05.059
That looks great.

66
02:05.059 --> 02:06.766
All right, so what we want to do is go back

67
02:06.766 --> 02:08.270
to the NSX Manager.

68
02:08.270 --> 02:10.009
So, here we have the NSX Manager.

69
02:10.009 --> 02:13.370
And let's go ahead and create some IP pools.

70
02:13.370 --> 02:14.870
So, to do that, we're going to click

71
02:14.870 --> 02:17.690
on the networking tab right here at the top.

72
02:17.690 --> 02:19.830
Here is giving us a nice network overview.

73
02:19.830 --> 02:21.570
We have pretty much nothing going on

74
02:21.570 --> 02:24.010
as far as layer three routing or anything else.

75
02:24.010 --> 02:26.010
So, what we're going to scroll down on the left,

76
02:26.010 --> 02:27.650
we're going to go down under IP management

77
02:27.650 --> 02:30.120
and click right here on IP address pools.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

77
02:27.650 --> 02:30.120
and click right here on IP address pools.

78
02:30.120 --> 02:32.309
And then there's no IP address pools by default.

79
02:32.309 --> 02:34.139
So, let's go ahead and create some.

80
02:34.139 --> 02:36.670
So, click here on add IP address pool.

81
02:36.670 --> 02:38.020
And let's name this pool.

82
02:38.020 --> 02:40.480
I'm going to go ahead and call it 10.11.11.

83
02:40.480 --> 02:42.620
So, I'll remember what it is just by looking at it.

84
02:42.620 --> 02:43.740
And then we'll click right here

85
02:43.740 --> 02:45.940
on set underneath the subnets column.

86
02:45.940 --> 02:47.540
We'll click add subnet.

87
02:47.540 --> 02:49.560
And let's do a range of addresses.

88
02:49.560 --> 02:50.620
And how about for this one?

89
02:50.620 --> 02:55.323
We'll do 10.11.11.151

90
02:55.323 --> 02:58.429
through 10.11.11.200.

91
02:58.429 --> 03:00.379
And that'll be 50 addresses that are available.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

91
02:58.429 --> 03:00.379
And that'll be 50 addresses that are available.

92
03:00.379 --> 03:02.150
Then also specify the length of the mask

93
03:02.150 --> 03:03.240
with the cider notation.

94
03:03.240 --> 03:07.579
So, it'll be in the 10.11.11.0 with a /24.

95
03:07.579 --> 03:09.120
We'll hit tab.

96
03:09.120 --> 03:10.330
And then for the gateway address, this is important

97
03:10.330 --> 03:12.830
because if we have a device that gets an IP address

98
03:12.830 --> 03:15.009
on the 10.11.11 network,

99
03:15.009 --> 03:18.450
and it needs to route or reach some other destination,

100
03:18.450 --> 03:20.250
it's going to need a default gateway.

101
03:20.250 --> 03:23.650
So, the switch that we configured in the previous video,

102
03:23.650 --> 03:26.110
it's at 10.11.11.1.

103
03:26.110 --> 03:27.870
And that's the IP address we configured on it.

104
03:27.870 --> 03:29.639
It'll act as the default gateway.

105
03:29.639 --> 03:30.969
And then for the DNS servers,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

105
03:29.639 --> 03:30.969
And then for the DNS servers,

106
03:30.969 --> 03:32.880
we'll put the management DNS server

107
03:32.880 --> 03:36.039
at 192.168.1.100.

108
03:36.039 --> 03:37.860
We also want to make sure

109
03:37.860 --> 03:38.950
that that's going to be reachable

110
03:38.950 --> 03:40.360
by a client if it needs it.

111
03:40.360 --> 03:41.730
And then for the DNS suffix,

112
03:41.730 --> 03:44.120
let's go ahead and use ogit.local.

113
03:44.120 --> 03:46.690
That's the suffix I'm using in my lab here.

114
03:46.690 --> 03:48.059
All right.

115
03:48.059 --> 03:48.630
So, we'll click on add.

116
03:48.630 --> 03:51.049
And then we'll click on apply down here.

117
03:51.049 --> 03:52.660
And then we'll click on save.

118
03:52.660 --> 03:56.580
And boom, we now have a pool called pool 10.11.11.

119
03:56.580 --> 03:58.530
Let's make one more

120
03:58.530 --> 04:00.750
for the 10.22.22 network address space.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

120
03:58.530 --> 04:00.750
for the 10.22.22 network address space.

121
04:00.750 --> 04:03.059
So, we'll click on the add IP address pool.

122
04:03.059 --> 04:06.420
We'll call it pool 10.22.22.

123
04:06.420 --> 04:07.700
We'll tab over a couple of times.

124
04:07.700 --> 04:10.139
Click on set right here for the subnets

125
04:10.139 --> 04:11.770
and click on add subnet.

126
04:11.770 --> 04:13.370
And then click on IP ranges.

127
04:13.370 --> 04:16.790
And let's use the range of 10.22.22.

128
04:16.790 --> 04:18.720
And to be consistent,

129
04:18.720 --> 04:22.089
let's just use 151 through 10.22.22.200.

130
04:22.089 --> 04:23.690
And 50 addresses will be more

131
04:23.690 --> 04:24.849
than enough for my lab environment.

132
04:24.849 --> 04:27.990
And then for the network address space that we're in,

133
04:27.990 --> 04:30.940
I'll specify it's 10.22.22.0
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

133
04:27.990 --> 04:30.940
I'll specify it's 10.22.22.0

134
04:30.940 --> 04:32.290
with a 24-bit mask.

135
04:32.290 --> 04:35.990
And then we'll specify the default gateway, 10.22.22.1.

136
04:35.990 --> 04:37.650
That's the switched virtual interface

137
04:37.650 --> 04:38.990
that we looked at in the previous video

138
04:38.990 --> 04:41.660
on my multilayer switch on the physical network.

139
04:41.660 --> 04:44.319
So, my DNS server is 192.168.1.100.

140
04:44.319 --> 04:46.930
And the DNS suffix is ogit.local.

141
04:46.930 --> 04:48.480
So, the actual DNS suffix

142
04:48.480 --> 04:50.500
and the DNS server is going to be too critical

143
04:50.500 --> 04:53.770
for our ESXi host if they're using this IP address space.

144
04:53.770 --> 04:56.660
But what will be important is the default gateway should

145
04:56.660 --> 04:58.690
the need to route or reach

146
04:58.690 --> 05:00.280
another tunnel endpoint, for example,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

146
04:58.690 --> 05:00.280
another tunnel endpoint, for example,

147
05:00.280 --> 05:03.250
from ESXi A to ESXi B or vice versa,

148
05:03.250 --> 05:04.779
that's on a different subnet.

149
05:04.779 --> 05:07.790
So, I'll click on add here and click on apply,

150
05:07.790 --> 05:09.070
and click on save.

151
05:09.070 --> 05:11.560
And now we have two pools of addresses,

152
05:11.560 --> 05:15.320
one called 10.11.11, one called 10.22.22,

153
05:15.320 --> 05:17.180
which are both available.

154
05:17.180 --> 05:17.760
So over here,

155
05:17.760 --> 05:18.940
it says this second one is not yet initialized.

156
05:18.940 --> 05:21.530
So, we'll click on the refresh button and boom,

157
05:21.530 --> 05:23.620
now it's ready to go.

158
05:23.620 --> 05:24.800
Now, the way we communicate to an ESXi host

159
05:24.800 --> 05:27.480
about which of the uplinks it should use

160
05:27.480 --> 05:29.030
for the NSX traffic,

161
05:29.030 --> 05:31.610
we are going to use what's called an uplink profile.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

161
05:29.030 --> 05:31.610
we are going to use what's called an uplink profile.

162
05:31.610 --> 05:32.830
So, that'll be our next step,

163
05:32.830 --> 05:34.160
and let's create three of them.

164
05:34.160 --> 05:36.580
We'll create one uplink profile that says

165
05:36.580 --> 05:38.679
to ESXi-A use these two ports

166
05:38.679 --> 05:40.430
and VLAN 101.

167
05:40.430 --> 05:42.020
We'll create one uplink profile

168
05:42.020 --> 05:44.030
that we're going to use with ESXi-B that's going to say

169
05:44.030 --> 05:47.080
use these two uplinks and VLAN 102.

170
05:47.080 --> 05:49.580
We'll also specify the appropriate IP address.

171
05:49.580 --> 05:52.740
We'll also create a third uplink profile in the event

172
05:52.740 --> 05:55.142
that we want to configure a whole cluster

173
05:55.142 --> 05:57.400
of ESXi hosts as transport nodes

174
05:57.400 --> 05:59.509
all at the same time.

175
05:59.509 --> 05:59.959
And if we do that, we then could refer

176
05:59.959 --> 06:02.570
to the common uplink profile
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

176
05:59.959 --> 06:02.570
to the common uplink profile

177
06:02.570 --> 06:03.990
that they would then both use.

178
06:03.990 --> 06:05.960
So, let's go back to the NSX manager

179
06:05.960 --> 06:07.980
and let's create our uplink profiles.

180
06:07.980 --> 06:10.030
So back here at the NSX manager,

181
06:10.030 --> 06:13.330
the question is where are the uplink profiles kept?

182
06:13.330 --> 06:14.610
Where do we go to configure them?

183
06:14.610 --> 06:17.529
And the answer to that is by going here to system.

184
06:17.529 --> 06:19.840
And here at the top with system selected on the left,

185
06:19.840 --> 06:21.950
we are going to expand the fabric

186
06:21.950 --> 06:24.090
section here.

187
06:24.090 --> 06:24.180
And with fabric expanded,

188
06:24.180 --> 06:26.849
we're going to click right here on profiles.

189
06:26.849 --> 06:27.990
So, here are profiles.

190
06:27.990 --> 06:30.170
Instead of using one of the default ones
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

190
06:27.990 --> 06:30.170
Instead of using one of the default ones

191
06:30.170 --> 06:32.380
that's currently in place, let's create one.

192
06:32.380 --> 06:33.530
In fact, we're going to create three.

193
06:33.530 --> 06:36.550
We're going to create one for ESXi-A, one for ESXi-B,

194
06:36.550 --> 06:38.320
and also one that we could use

195
06:38.320 --> 06:40.940
if we're configuring a whole cluster at the same time.

196
06:40.940 --> 06:45.830
So, for this first one, let's call it ESXi-A uplink V101

197
06:45.830 --> 06:46.970
to represent that we are going

198
06:46.970 --> 06:50.280
to be using VLAN 101 for the transport network

199
06:50.280 --> 06:53.000
if this uplink profile is called upon.

200
06:53.000 --> 06:55.150
And then if we're using link aggregation,

201
06:55.150 --> 06:58.130
think of like link aggregation control protocol

202
06:58.130 --> 07:00.380
and ether channel bundles in the world of Cisco.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

202
06:58.130 --> 07:00.380
and ether channel bundles in the world of Cisco.

203
07:00.380 --> 07:01.630
If you have those set up and you want

204
07:01.630 --> 07:03.400
to use those link aggregation groups,

205
07:03.400 --> 07:05.809
you could specify them here in my lab environment.

206
07:05.809 --> 07:07.750
I'm simply using single interfaces.

207
07:07.750 --> 07:09.450
So, we're going to go down to teamings

208
07:09.450 --> 07:11.329
and we're going to simply use

209
07:11.329 --> 07:12.150
the default teaming method.

210
07:12.150 --> 07:14.070
So, here the current default method here

211
07:14.070 --> 07:15.440
is failover order.

212
07:15.440 --> 07:17.030
So, it's going to use the active uplinks,

213
07:17.030 --> 07:19.710
whatever we have set here, followed by standby.

214
07:19.710 --> 07:21.740
So, if we want to change that, we could double click,

215
07:21.740 --> 07:23.100
and you could say I want to load balance

216
07:23.100 --> 07:24.690
based on source or load balance based

217
07:24.690 --> 07:26.870
on source MAC address.

218
07:26.870 --> 07:28.160
But for our purposes, we want to failover order,

219
07:28.160 --> 07:30.150
and I want to use a single uplink because
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

219
07:28.160 --> 07:30.150
and I want to use a single uplink because

220
07:30.150 --> 07:32.480
that's going to give us a single tap, a total endpoint,

221
07:32.480 --> 07:34.560
and that's going to make it much easier to track.

222
07:34.560 --> 07:36.540
So, for ESXi-A,

223
07:36.540 --> 07:40.070
let's go ahead and call the first active uplink.

224
07:40.070 --> 07:44.099
Let's call it use-VMNIC-2.

225
07:44.099 --> 07:45.839
And that's also going to help remind me

226
07:45.839 --> 07:48.650
which interface on the distributed switch I want

227
07:48.650 --> 07:50.920
to go ahead and use, which is going to be VMNIC 2

228
07:50.920 --> 07:52.850
for the first one, then for the standby.

229
07:52.850 --> 07:54.640
I'm going to go ahead and give this a label

230
07:54.640 --> 07:56.090
and I'm going to call this standby.

231
07:56.090 --> 07:57.220
And I'll put a dash three

232
07:57.220 --> 07:59.840
there just to remind myself this can be VMNIC 3.

233
07:59.840 --> 08:02.070
So, these labels are just associated
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

233
07:59.840 --> 08:02.070
So, these labels are just associated

234
08:02.070 --> 08:04.190
with this uplink profile, and they don't really

235
08:04.190 --> 08:07.550
mean anything until we use this uplink profile,

236
08:07.550 --> 08:10.410
specifically called ESXi-A uplink with V101.

237
08:10.410 --> 08:13.680
And we apply that in association with a transport host.

238
08:13.680 --> 08:14.929
So currently we have a name,

239
08:14.929 --> 08:17.820
we've specified the active and standby links here,

240
08:17.820 --> 08:19.240
the labels for them anyway.

241
08:19.240 --> 08:20.829
And then down here,

242
08:20.829 --> 08:22.520
we also want to specify the transport VLAN to use.

243
08:22.520 --> 08:26.150
So, for ESXi-A, if we want it to use VLAN 101

244
08:26.150 --> 08:28.300
for the transport network, we want to go ahead

245
08:28.300 --> 08:31.050
and put the transport VLAN 101 right here.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

245
08:28.300 --> 08:31.050
and put the transport VLAN 101 right here.

246
08:31.050 --> 08:33.620
And because with the current flavor of NSX,

247
08:33.620 --> 08:35.620
if we're using a virtual distributed switch

248
08:35.620 --> 08:39.130
in vSphere, which we are, and it has a huge MTU,

249
08:39.130 --> 08:40.340
we don't need to do anything

250
08:40.340 --> 08:43.110
about the MTU right here because the MTU, as it says,

251
08:43.110 --> 08:46.510
is not applicable for a virtual distributed switch.

252
08:46.510 --> 08:48.410
But at the same time, we also want to make sure

253
08:48.410 --> 08:49.920
that in the physical environment that

254
08:49.920 --> 08:53.700
we can support frames larger than the default of 1500.

255
08:53.700 --> 08:54.799
So, in the physical environment,

256
08:54.799 --> 08:56.580
I've got my Cisco switch set up

257
08:56.580 --> 08:58.430
to support 9,000 for the MTU.

258
08:58.430 --> 09:01.830
And when we deploy our distributed switch in vSphere,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

258
08:58.430 --> 09:01.830
And when we deploy our distributed switch in vSphere,

259
09:01.830 --> 09:05.010
we'll also set up a larger than default MTU as well.

260
09:05.010 --> 09:08.040
So, we'll click on add, and then we will check our work.

261
09:08.040 --> 09:13.040
So, for this profile called ESXi-A uplink with V101,

262
09:13.040 --> 09:14.830
we're using the transport VLAN of 101.

263
09:15.670 --> 09:17.410
Fantastic.

264
09:17.410 --> 09:18.469
And then we scroll down,

265
09:18.469 --> 09:19.470
we have our active uplink label

266
09:19.470 --> 09:22.110
and our standby uplink label set up.

267
09:22.110 --> 09:23.090
And that looks great.

268
09:23.090 --> 09:24.590
So, let's make one more for ESXi-B.

269
09:24.590 --> 09:27.530
So, we'll click on plus, and we'll go ahead

270
09:27.530 --> 09:30.930
and say this is going to be ESXi-B,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

270
09:27.530 --> 09:30.930
and say this is going to be ESXi-B,

271
09:30.930 --> 09:34.480
and I see a little copy paste action there with VLAN 102.

272
09:34.480 --> 09:35.980
I'll scroll down.

273
09:35.980 --> 09:38.600
I want to use VLAN 102 for the transport

274
09:38.600 --> 09:40.740
for this profile because we're going to associate

275
09:40.740 --> 09:42.370
this with ESXi-B.

276
09:42.370 --> 09:44.679
And for the actual uplinks,

277
09:44.679 --> 09:46.710
let's go ahead for the active uplink, let's go ahead

278
09:46.710 --> 09:49.670
and use DOS to remind myself in Spanish

279
09:49.670 --> 09:51.710
that I want to use uplink number two.

280
09:51.710 --> 09:54.410
And for the standby, we'll use trace,

281
09:54.410 --> 09:56.460
which is going to help mostly remind me

282
09:56.460 --> 09:59.370
that we are going to be using VMNIC 3.

283
09:59.370 --> 10:02.320
So again, in the uplink profiles, these are just labels,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

283
09:59.370 --> 10:02.320
So again, in the uplink profiles, these are just labels,

284
10:02.320 --> 10:04.320
which when we apply the uplink profiles,

285
10:04.320 --> 10:06.460
we'll associate with the actual uplinks

286
10:06.460 --> 10:07.830
on our distributed switch.

287
10:07.830 --> 10:09.610
So, we'll go ahead and click on add,

288
10:09.610 --> 10:11.000
and then we'll verify our work.

289
10:11.000 --> 10:14.220
So, for this uplink profile, ESXi-B uplink with V102,

290
10:14.220 --> 10:15.440
our VLAN is 102.

291
10:15.440 --> 10:17.260
That looks great.

292
10:17.260 --> 10:19.260
And for the teamings, I've got the first label

293
10:19.260 --> 10:21.380
and second label for the active and standby.

294
10:21.380 --> 10:22.410
That looks fantastic.

295
10:22.410 --> 10:25.110
And let's make one more that if we choose

296
10:25.110 --> 10:27.820
to deploy a whole cluster of ESXi hosts

297
10:27.820 --> 10:30.930
and make them transport nodes, we could refer to this.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

297
10:27.820 --> 10:30.930
and make them transport nodes, we could refer to this.

298
10:30.930 --> 10:32.910
So, we'll call this uplinks for cluster.

299
10:32.910 --> 10:35.030
And again, I don't have any link aggregation going on,

300
10:35.030 --> 10:37.090
so I'll go ahead for the teamings

301
10:37.090 --> 10:38.480
and I'll say for the teamings,

302
10:38.480 --> 10:39.540
let me go ahead

303
10:39.540 --> 10:43.043
and specify that instead of using a failover order,

304
10:43.043 --> 10:44.509
I wanna do load balancing.

305
10:44.509 --> 10:45.870
And let me put them both right here.

306
10:45.870 --> 10:49.280
So, I'll put two comma three, just as labels once again,

307
10:49.280 --> 10:51.580
to remind myself of which VM NICs,

308
10:51.580 --> 10:53.660
I hope to actually associate with those.

309
10:53.660 --> 10:56.920
And I intentionally made the actual labels here different

310
10:56.920 --> 10:59.020
on each of the uplink profiles.

311
10:59.020 --> 11:02.599
So, if we are going to use this uplinks for cluster profile,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

311
10:59.020 --> 11:02.599
So, if we are going to use this uplinks for cluster profile,

312
11:02.599 --> 11:03.750
what VLAN do we want to use?

313
11:03.750 --> 11:06.469
Let's just double up on VLAN 101.

314
11:06.469 --> 11:07.870
So, I'm going to add that to the title as well,

315
11:07.870 --> 11:09.600
just to remind myself when I see it

316
11:09.600 --> 11:12.580
about exactly which VLAN we're going to be using.

317
11:12.580 --> 11:15.741
If we choose to use this uplink profile called uplinks

318
11:15.741 --> 11:18.153
for cluster V101, and we'll click on add,

319
11:18.153 --> 11:20.690
then I'll verify my work there by clicking on it,

320
11:20.690 --> 11:23.430
and just verifying transport VLAN 101,

321
11:23.430 --> 11:26.260
and labels two and three for two active uplink.

322
11:26.260 --> 11:29.490
So, if we did use this uplink profile,

323
11:29.490 --> 11:31.570
because we have two active uplinks,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

323
11:29.490 --> 11:31.570
because we have two active uplinks,

324
11:31.570 --> 11:35.139
it's going to end up with two tunnel endpoint addresses,

325
11:35.139 --> 11:37.150
one for each of the active uplinks.

326
11:37.150 --> 11:40.420
So, at this point, we have our uplink profiles created.

327
11:40.420 --> 11:43.110
We haven't applied them yet to either of the ESXi host,

328
11:43.110 --> 11:44.670
but we'll get to that.

329
11:44.670 --> 11:46.280
But we do have the uplink profiles ready in the wings.

330
11:46.280 --> 11:48.680
We also have a couple of pools of IP addresses

331
11:48.680 --> 11:51.559
that we can pull from one in the 10.11.11 range,

332
11:51.559 --> 11:53.830
one in the 10.22.22 range.

333
11:53.830 --> 11:55.230
And so, for our next step,

334
11:55.230 --> 11:59.170
we are gonna create a new overlay transport zone.

335
11:59.170 --> 12:00.880
And just like our uplink profiles,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

335
11:59.170 --> 12:00.880
And just like our uplink profiles,

336
12:00.880 --> 12:03.140
they're really not going to be doing too much until

337
12:03.140 --> 12:05.070
we associate these objects,

338
12:05.070 --> 12:08.099
including the uplink profiles and the transport zones,

339
12:08.099 --> 12:09.889
until we associate them

340
12:09.889 --> 12:12.400
with an ESXi host that's been enabled for NSX,

341
12:12.400 --> 12:15.339
which is now going to be called a host transport node.

342
12:15.339 --> 12:16.959
So again, this is all in preparation

343
12:16.959 --> 12:19.310
for the actual deployment where we'll configure

344
12:19.310 --> 12:20.800
our ESXi host.

345
12:20.800 --> 12:21.940
So, join me in the next video

346
12:21.940 --> 12:24.420
as we create a brand-new transport zone

347
12:24.420 --> 12:25.610
that we can use as part of our configuration.
