WEBVTT

1
00:00.130 --> 00:00.963
So in this video,

2
00:00.963 --> 00:03.360
I'd like to go ahead and take care of both of these items

3
00:03.360 --> 00:05.190
because one is just a couple clicks

4
00:05.190 --> 00:08.940
and that is to create a brand new overlay transport zone

5
00:08.940 --> 00:10.500
inside of NSX.

6
00:10.500 --> 00:12.870
So that'll be just a couple clicks to create one.

7
00:12.870 --> 00:14.100
And then secondly,

8
00:14.100 --> 00:16.980
let's go over to the vSphere client using vCenter

9
00:16.980 --> 00:19.860
and let's create a new distributed switch in vCenter

10
00:19.860 --> 00:23.760
that we will then use in the future for the purposes of NSX.

11
00:23.760 --> 00:26.220
And when we do so, let's also set the MTU

12
00:26.220 --> 00:28.110
to an MTU of 9000,

13
00:28.110 --> 00:29.940
which goes above and beyond the requirement

14
00:29.940 --> 00:32.010
of a minimum of 1700
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

14
00:29.940 --> 00:32.010
of a minimum of 1700

15
00:32.010 --> 00:34.080
because of the encapsulation requirement

16
00:34.080 --> 00:36.720
with the tunnel end points as part of the GENEVE tunnels.

17
00:36.720 --> 00:38.460
So if we set the MTU to 9000,

18
00:38.460 --> 00:40.080
we'll have plenty of room to spare.

19
00:40.080 --> 00:42.240
So back to the NSX manager we go,

20
00:42.240 --> 00:45.750
so we left off under System and Profiles

21
00:45.750 --> 00:48.720
and Uplink Profiles, and we created three uplink profiles,

22
00:48.720 --> 00:49.800
which are right here.

23
00:49.800 --> 00:52.260
And to create a brand new transport zone,

24
00:52.260 --> 00:53.910
we're gonna stay right here at System.

25
00:53.910 --> 00:55.650
But on the left under Fabric,

26
00:55.650 --> 00:57.930
we're gonna go down one more below Profiles

27
00:57.930 --> 00:59.340
to Transport Zones.

28
00:59.340 --> 01:02.280
So there is a default overlay
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

28
00:59.340 --> 01:02.280
So there is a default overlay

29
01:02.280 --> 01:04.080
and VLAN backed transport zone,

30
01:04.080 --> 01:05.460
but we're gonna create our own.

31
01:05.460 --> 01:08.520
So let's go ahead and click on Add Transport Zone,

32
01:08.520 --> 01:13.520
and let's call this Our A-B Overlay TZ, for transport zone.

33
01:15.270 --> 01:16.597
And that way when we see it, we'll know,

34
01:16.597 --> 01:17.970
"Oh, that's the one we created."

35
01:17.970 --> 01:21.870
And then for the type of transport zone, there's two types.

36
01:21.870 --> 01:24.300
One that's gonna support NSX segments

37
01:24.300 --> 01:25.650
that are overlay segments

38
01:25.650 --> 01:28.290
where the traffic is being tunneled or can be tunneled,

39
01:28.290 --> 01:31.110
and the other's four VLAN-backed NSX segments.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

39
01:28.290 --> 01:31.110
and the other's four VLAN-backed NSX segments.

40
01:31.110 --> 01:32.490
So what we're gonna do is we're gonna set up

41
01:32.490 --> 01:34.620
a new transport zone called this

42
01:34.620 --> 01:37.410
that is gonna support overlay network segments.

43
01:37.410 --> 01:39.870
So think of the overlay as the process

44
01:39.870 --> 01:41.880
of using the GENEVE tunnels

45
01:41.880 --> 01:45.180
to take VMs traffic or user's traffic,

46
01:45.180 --> 01:47.310
encapsulate it and be able to send it over the tunnel.

47
01:47.310 --> 01:50.100
So once we have this new overlay zone created,

48
01:50.100 --> 01:53.130
then we can specify which ESXi host transport nodes

49
01:53.130 --> 01:56.280
are gonna be supporting and included as part of this zone.

50
01:56.280 --> 01:59.160
And then furthermore, when we create overlay segments,

51
01:59.160 --> 02:01.530
we can associate those segments within a zone.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

51
01:59.160 --> 02:01.530
we can associate those segments within a zone.

52
02:01.530 --> 02:03.870
So all we have to do is name it, specify the type,

53
02:03.870 --> 02:05.760
and we don't have to specify any limitations

54
02:05.760 --> 02:07.230
regarding VLANs or anything else,

55
02:07.230 --> 02:08.520
and we'll click on Save.

56
02:08.520 --> 02:10.410
So there it is right there.

57
02:10.410 --> 02:11.730
And for the second part of this video,

58
02:11.730 --> 02:14.220
we are going to create our distributed switch

59
02:14.220 --> 02:16.800
that we're then going to use with NSX.

60
02:16.800 --> 02:18.210
So to create the distributed switch,

61
02:18.210 --> 02:20.790
we'll use the vSphere client connected to vCenter

62
02:20.790 --> 02:22.590
to create that distributed switch,

63
02:22.590 --> 02:24.777
and we'll name it DS for NSX,

64
02:24.777 --> 02:26.700
and we'll set the MTU to 9000.

65
02:26.700 --> 02:29.040
So we're gonna hop over to the vSphere Client.

66
02:29.040 --> 02:30.390
So here at the vSphere Client,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

66
02:29.040 --> 02:30.390
So here at the vSphere Client,

67
02:30.390 --> 02:33.330
we're logged on as Administrator@VSPHERE.LOCAL.

68
02:33.330 --> 02:34.470
Here in the vSphere Client,

69
02:34.470 --> 02:36.237
we'll click on the Networking tab.

70
02:36.237 --> 02:39.480
And we currently have one virtual distributed switch.

71
02:39.480 --> 02:40.890
It's called VDS for management.

72
02:40.890 --> 02:42.360
And what we wanna do is we wanna create

73
02:42.360 --> 02:44.070
a new distributed switch.

74
02:44.070 --> 02:46.560
So to do that, we'll right click on our DataCenter

75
02:46.560 --> 02:49.140
from the dropdown, we'll click on Distributed Switch,

76
02:49.140 --> 02:52.230
and from the submenu, we'll click on New Distributed Switch.

77
02:52.230 --> 02:56.340
And based on our game plan, we'll call it DS for NSX,

78
02:56.340 --> 02:57.840
and click on Next.

79
02:57.840 --> 02:59.850
And then we'll choose the latest, greatest version

80
02:59.850 --> 03:00.750
of the distributed switch.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

80
02:59.850 --> 03:00.750
of the distributed switch.

81
03:00.750 --> 03:01.680
Fantastic.

82
03:01.680 --> 03:02.820
we'll click on Next.

83
03:02.820 --> 03:04.260
And as far as the settings,

84
03:04.260 --> 03:05.250
for this distributed switch,

85
03:05.250 --> 03:06.960
we want to have at least two uplinks.

86
03:06.960 --> 03:09.270
So I'm gonna go ahead and say two uplinks

87
03:09.270 --> 03:11.580
are gonna be included as part of this distributed switch.

88
03:11.580 --> 03:13.350
And then I also am not, for the moment,

89
03:13.350 --> 03:14.820
going to create a default port group

90
03:14.820 --> 03:16.200
and there's a couple reasons for that.

91
03:16.200 --> 03:17.033
One, we could.

92
03:17.033 --> 03:18.270
We could create a default port group,

93
03:18.270 --> 03:20.430
but I'm gonna have all of the segments

94
03:20.430 --> 03:22.500
that show up as part of NSX,

95
03:22.500 --> 03:25.560
they're gonna show up as if they are port groups

96
03:25.560 --> 03:27.180
under this distributed switch.

97
03:27.180 --> 03:28.170
So they're called segments,

98
03:28.170 --> 03:31.260
but they kinda look and feel a lot like port groups.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

98
03:28.170 --> 03:31.260
but they kinda look and feel a lot like port groups.

99
03:31.260 --> 03:33.240
So I'm not gonna create a default port group

100
03:33.240 --> 03:35.850
and click on next and then click on finish.

101
03:35.850 --> 03:37.560
So now, if we go do our distributed switch,

102
03:37.560 --> 03:39.480
I also wanna make sure that we set it up

103
03:39.480 --> 03:41.160
with an MTU of 9000.

104
03:41.160 --> 03:43.500
So I'm gonna right click on our distributed switch

105
03:43.500 --> 03:45.450
and click on the Settings option here,

106
03:45.450 --> 03:47.460
click on Edit Settings right there.

107
03:47.460 --> 03:49.260
And then specify under Advanced

108
03:49.260 --> 03:51.600
that we want it to not use the default of 1500 bytes,

109
03:51.600 --> 03:53.580
but rather 9000.

110
03:53.580 --> 03:56.520
And that will more than cover the requirement of 1700.

111
03:56.520 --> 03:57.930
And then also while we're here,

112
03:57.930 --> 04:00.690
I'm gonna enable Link Layer Discovery Protocol,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

112
03:57.930 --> 04:00.690
I'm gonna enable Link Layer Discovery Protocol,

113
04:00.690 --> 04:02.340
both sending and receiving,

114
04:02.340 --> 04:03.750
and then also for our uplinks,

115
04:03.750 --> 04:06.090
instead of calling 'em Uplink 1 and Uplink 2,

116
04:06.090 --> 04:07.770
I wanna make it really clear

117
04:07.770 --> 04:10.770
when you see these and when we map the uplink profiles

118
04:10.770 --> 04:12.450
to the uplinks on the distributed switch,

119
04:12.450 --> 04:15.060
I wanna be very clear on which ones these are.

120
04:15.060 --> 04:20.060
So here, I'm gonna label this as DS vmnic 2,

121
04:20.940 --> 04:24.930
and here, I'm gonna call the second one DS vmnic 3,

122
04:24.930 --> 04:27.097
And that way when you see those terms, you'll know,

123
04:27.097 --> 04:30.510
"Oh, those are the actual names of the uplinks
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

123
04:27.097 --> 04:30.510
"Oh, those are the actual names of the uplinks

124
04:30.510 --> 04:31.860
on the distributed switch."

125
04:31.860 --> 04:33.480
And then we'll take a further step in a moment

126
04:33.480 --> 04:35.520
and we'll bring on our ESXi host

127
04:35.520 --> 04:37.410
and map those two uplinks

128
04:37.410 --> 04:40.650
to their respective vmnic 2 and vmnic 3 interfaces.

129
04:40.650 --> 04:42.360
So let me just check my work real quick here.

130
04:42.360 --> 04:43.740
So under General, we're good.

131
04:43.740 --> 04:45.360
Advanced, 9000.

132
04:45.360 --> 04:48.270
Link Layer Discovery Protocol, both directions.

133
04:48.270 --> 04:50.130
And then two uplinks, that looks great.

134
04:50.130 --> 04:51.510
So we'll click on Okay.

135
04:51.510 --> 04:52.800
And now for that distributed switch,

136
04:52.800 --> 04:54.330
if we click on Configure

137
04:54.330 --> 04:56.990
and we click on Topology, there it is,

138
04:56.990 --> 04:59.490
so we have this logical distributed switch,

139
04:59.490 --> 05:01.830
absolutely no port groups whatsoever here
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

139
04:59.490 --> 05:01.830
absolutely no port groups whatsoever here

140
05:01.830 --> 05:05.010
for VMs or for VM kernel adapters.

141
05:05.010 --> 05:07.830
And over here on the right, we have two labels,

142
05:07.830 --> 05:09.510
but there's no network interface cards

143
05:09.510 --> 05:11.280
associated with either one of them.

144
05:11.280 --> 05:15.420
So to fix that, we are going to onboard our two ESXi host,

145
05:15.420 --> 05:18.150
A and B, and have them both participate

146
05:18.150 --> 05:19.440
with this distributed switch.

147
05:19.440 --> 05:20.490
So to do that,

148
05:20.490 --> 05:22.320
we're gonna go ahead back to the distributed switch,

149
05:22.320 --> 05:24.120
right click on that distributed switch,

150
05:24.120 --> 05:26.817
and from the dropdown click Add and Manage Hosts.

151
05:26.817 --> 05:29.010
And then here, we'll click on add hosts

152
05:29.010 --> 05:30.630
because we currently don't have any hosts
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

152
05:29.010 --> 05:30.630
because we currently don't have any hosts

153
05:30.630 --> 05:32.280
that are using this distributed switch.

154
05:32.280 --> 05:33.450
We'll click on next.

155
05:33.450 --> 05:35.820
And then let's bring in A and B.

156
05:35.820 --> 05:39.120
So host C and D are both in our management cluster,

157
05:39.120 --> 05:40.380
and we really don't need them

158
05:40.380 --> 05:41.610
to use this distributed switch.

159
05:41.610 --> 05:43.140
We're just gonna have A and B use it.

160
05:43.140 --> 05:45.630
So we'll select A and B, we'll click on Next.

161
05:45.630 --> 05:48.690
And then regarding which of the physical uplinks

162
05:48.690 --> 05:51.300
we want to associate, it's a good thing I named them.

163
05:51.300 --> 05:52.920
So if we go to vmnic 2 here

164
05:52.920 --> 05:56.700
and use the dropdown DS vmnic 2 is the label

165
05:56.700 --> 05:57.660
on the distributed switch,

166
05:57.660 --> 06:00.750
which we are gonna map to vmnic 2 on both those hosts.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

166
05:57.660 --> 06:00.750
which we are gonna map to vmnic 2 on both those hosts.

167
06:00.750 --> 06:03.540
And then for vmnic 3, we're gonna map that

168
06:03.540 --> 06:06.870
to this uplink label called DS vmnic 3.

169
06:06.870 --> 06:07.890
And that looks good too.

170
06:07.890 --> 06:08.940
We'll click on Next.

171
06:08.940 --> 06:11.400
And I'm not gonna bring over any VM kernel adapters.

172
06:11.400 --> 06:12.960
I'm gonna leave them where they're at.

173
06:12.960 --> 06:15.060
And I'm also not gonna migrate any virtual machines.

174
06:15.060 --> 06:16.380
I'm gonna leave them where they're at,

175
06:16.380 --> 06:17.670
and we'll click on Next.

176
06:17.670 --> 06:20.100
Here's a summary, two hosts with two adapters each

177
06:20.100 --> 06:22.380
for a total of four physical adapters being mapped

178
06:22.380 --> 06:23.730
as part of this distributed switch.

179
06:23.730 --> 06:25.110
And we'll click on Finish,

180
06:25.110 --> 06:27.180
and we'll go ahead and refresh this.

181
06:27.180 --> 06:29.610
And now if we expand the uplinks here,

182
06:29.610 --> 06:33.630
we have this labeled DS vmnic 2 with two uplinks,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

182
06:29.610 --> 06:33.630
we have this labeled DS vmnic 2 with two uplinks,

183
06:33.630 --> 06:36.780
one on esxi-a and B using vmnic 2 on each.

184
06:36.780 --> 06:39.630
And then for the labeled DS vmnic 3,

185
06:39.630 --> 06:42.690
we have two uplinks, one on esxi-a and one on esxi-b.

186
06:42.690 --> 06:43.530
That looks great.

187
06:43.530 --> 06:45.120
We can also verify that

188
06:45.120 --> 06:46.890
with the distributed switch selected,

189
06:46.890 --> 06:49.260
clicking on Hosts, verifying we have the two hosts here,

190
06:49.260 --> 06:50.160
that looks great.

191
06:50.160 --> 06:52.050
We could also go to the individual hosts,

192
06:52.050 --> 06:53.430
then we'll select esxi-a

193
06:53.430 --> 06:55.590
click on Configure and Virtual switches,

194
06:55.590 --> 06:56.940
and there it is right there.

195
06:56.940 --> 06:58.860
So currently, there's no port groups

196
06:58.860 --> 07:00.240
or anything else using that.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

196
06:58.860 --> 07:00.240
or anything else using that.

197
07:00.240 --> 07:02.580
And if we look at esxi-b, very similar.

198
07:02.580 --> 07:04.170
If we go to esxi-c,

199
07:04.170 --> 07:06.600
it doesn't have that new distributed switch at all

200
07:06.600 --> 07:08.640
because we didn't associate that distributed switch

201
07:08.640 --> 07:11.340
with esxi-c or esxi-d.

202
07:11.340 --> 07:13.350
So now if we go back to the Networking tab,

203
07:13.350 --> 07:16.810
we have this new distributed switch called DS for NSX.

204
07:16.810 --> 07:19.260
If we click on Configure and Topology,

205
07:19.260 --> 07:22.260
gives a bird's eye view of the network interface cards,

206
07:22.260 --> 07:24.420
the vmnics on each of the ESXi hosts

207
07:24.420 --> 07:27.750
that are participating as part of that distributed switch.

208
07:27.750 --> 07:30.600
And that means that our last step is this one right here,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

208
07:27.750 --> 07:30.600
And that means that our last step is this one right here,

209
07:30.600 --> 07:33.300
where we're going to go to the NSX manager

210
07:33.300 --> 07:38.300
and specify that we want to include ESXi-A and ESXi-B

211
07:38.850 --> 07:41.400
and install the NSX software on them,

212
07:41.400 --> 07:46.380
thus making them host transport nodes in our NSX ecosystem.

213
07:46.380 --> 07:48.900
So we'll go ahead and do the deployment of the NSX

214
07:48.900 --> 07:51.180
on those two hosts in the very next video.

215
07:51.180 --> 07:53.133
So I'll see you there in just a moment.
