WEBVTT

1
00:00.180 --> 00:01.290
So for our deployment,

2
00:01.290 --> 00:02.940
we should also just take a moment

3
00:02.940 --> 00:04.950
and verify a couple of things.

4
00:04.950 --> 00:07.590
Number one, if we are gonna be using Uplink three

5
00:07.590 --> 00:10.950
and VLAN 103 for Edge-1 and Uplink three

6
00:10.950 --> 00:14.760
and VLAN 104 as the transport VLAN, we wanna make sure

7
00:14.760 --> 00:17.040
that we have Uplink profiles currently in place,

8
00:17.040 --> 00:18.810
and if we don't, we'd wanna go ahead and create them.

9
00:18.810 --> 00:21.277
So we'd create an Uplink profile that says

10
00:21.277 --> 00:25.320
"Hey, please use the VLAN 103 and one for 104".

11
00:25.320 --> 00:27.930
And we'd also specify in those same Uplink profiles

12
00:27.930 --> 00:29.790
that we wanna use Uplink three.

13
00:29.790 --> 00:32.940
So for Edge-1, that'll be Uplink three on Edge-A,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

13
00:29.790 --> 00:32.940
So for Edge-1, that'll be Uplink three on Edge-A,

14
00:32.940 --> 00:34.920
and for Edge-2, that'd be Uplink three

15
00:34.920 --> 00:36.960
over here on ESXI-B.

16
00:36.960 --> 00:39.270
And then over on the Transport Network, we'd also be wise

17
00:39.270 --> 00:41.130
to take a moment just to verify

18
00:41.130 --> 00:43.140
that we have those existing VLANs

19
00:43.140 --> 00:45.600
and also that we have the routing capability

20
00:45.600 --> 00:49.140
between the 33 network and the 44 network space.

21
00:49.140 --> 00:50.970
Because if they have to route between each other,

22
00:50.970 --> 00:53.700
we wanna make sure we have all those routing services on the

23
00:53.700 --> 00:56.220
physical network provided by, or through

24
00:56.220 --> 00:57.540
our top of rack switches.

25
00:57.540 --> 00:59.730
So to give us a little bias towards success,

26
00:59.730 --> 01:00.960
let's take a moment right now
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

26
00:59.730 --> 01:00.960
let's take a moment right now

27
01:00.960 --> 01:03.930
and verify some of those infrastructure components

28
01:03.930 --> 01:05.490
and make sure that they're in place.

29
01:05.490 --> 01:07.380
So let's start with the infrastructure.

30
01:07.380 --> 01:09.960
This is gonna represent our top of rack switch.

31
01:09.960 --> 01:11.640
And let's go ahead and just verify

32
01:11.640 --> 01:13.830
with the Cisco Catalyst switch,

33
01:13.830 --> 01:15.570
which happens to be a multi-layer switch,

34
01:15.570 --> 01:17.820
so it can do layer two switching and also routing.

35
01:17.820 --> 01:19.560
So let's do a show VLAN brief.

36
01:19.560 --> 01:22.090
There is VLAN 103

37
01:22.090 --> 01:23.550
and VLAN 104.

38
01:23.550 --> 01:24.720
They both exist.

39
01:24.720 --> 01:26.730
So let's also do a show IP interface brief.

40
01:26.730 --> 01:27.840
Then I'm gonna use a pipe symbol,

41
01:27.840 --> 01:32.190
say please exclude in the output anything that has the word
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

41
01:27.840 --> 01:32.190
say please exclude in the output anything that has the word

42
01:32.190 --> 01:34.770
or the string of text U-N-A-S-S-I

43
01:34.770 --> 01:36.930
for unassigned and press enter.

44
01:36.930 --> 01:39.780
And here are logical layer three interfaces.

45
01:39.780 --> 01:41.880
So I've got routing capabilities

46
01:41.880 --> 01:42.900
with an IP address

47
01:42.900 --> 01:46.380
in VLAN 103 of 33, 33, 33.1,

48
01:46.380 --> 01:48.342
and a VLAN 104

49
01:48.342 --> 01:49.675
of 44, 44, 44.1.

50
01:50.532 --> 01:53.340
So if we do a show IP route, I've got routing capability

51
01:53.340 --> 01:54.960
between those two network address spaces.

52
01:54.960 --> 01:58.200
So there's my route for the 33 et cetera network.

53
01:58.200 --> 02:01.140
And here's my route for the 44 network.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

53
01:58.200 --> 02:01.140
And here's my route for the 44 network.

54
02:01.140 --> 02:03.630
And on this multilayer switch, it is directly connected

55
02:03.630 --> 02:06.330
to both networks via its VLAN interfaces.

56
02:06.330 --> 02:09.120
So I just wanna verify that we have the physical components

57
02:09.120 --> 02:11.520
ready to go to support our Edge nodes.

58
02:11.520 --> 02:13.890
So this top of rack switch has not only the VLANs

59
02:13.890 --> 02:16.560
but also has the routing for the IP subnets

60
02:16.560 --> 02:18.630
associated with those VLANs.

61
02:18.630 --> 02:21.450
And I've also got, I believe, DHCP services set up should we

62
02:21.450 --> 02:23.519
choose to use those as well.

63
02:23.519 --> 02:26.580
So if we do a show IP DHCP pool and press enter,

64
02:26.580 --> 02:30.480
I've got a pool for the 33 address base right there,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

64
02:26.580 --> 02:30.480
I've got a pool for the 33 address base right there,

65
02:30.480 --> 02:32.160
and another one for the 44 address base.

66
02:32.160 --> 02:35.407
So in the event for our Edge nodes, if we wanna say

67
02:35.407 --> 02:37.560
"Hey, use a DHCP assigned address",

68
02:37.560 --> 02:38.910
we have that option as well.

69
02:38.910 --> 02:40.350
However, for our purposes,

70
02:40.350 --> 02:43.110
we're gonna hard code the tunnel endpoint addresses

71
02:43.110 --> 02:45.750
as 3 3, 3 3, 3 3, 3 3

72
02:45.750 --> 02:47.250
for Edge-1

73
02:47.250 --> 02:49.920
and 44, 44, 44, 44

74
02:49.920 --> 02:50.790
for Edge-2.

75
02:50.790 --> 02:52.380
And that way when we see those IP address,

76
02:52.380 --> 02:54.000
we'll know exactly what they are.

77
02:54.000 --> 02:56.640
Next, let's head over to the NSX manager to verify

78
02:56.640 --> 02:58.950
that we have Uplink profiles that we can use

79
02:58.950 --> 03:00.900
for Edge-1 and Edge-2.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

79
02:58.950 --> 03:00.900
for Edge-1 and Edge-2.

80
03:00.900 --> 03:04.590
So here in the NSX manager, let's go to the system tab.

81
03:04.590 --> 03:06.660
And under fabric on the left, we're gonna go down

82
03:06.660 --> 03:08.070
to profiles.

83
03:08.070 --> 03:10.470
And so here's a bunch of Uplink profiles

84
03:10.470 --> 03:13.620
that I made previously and we can just pick one

85
03:13.620 --> 03:14.940
or two of those and verify they're

86
03:14.940 --> 03:16.380
correct before we use them.

87
03:16.380 --> 03:20.760
So for Edge-1 it's gonna be using Uplink three

88
03:20.760 --> 03:22.860
on its respective host that's running it

89
03:22.860 --> 03:26.670
and it's gonna use on that Uplink VLAN 103.

90
03:26.670 --> 03:28.980
So that looks like a winner right there.

91
03:28.980 --> 03:31.230
If we just click on it to confirm.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

91
03:28.980 --> 03:31.230
If we just click on it to confirm.

92
03:31.230 --> 03:35.700
So this Uplink profile called V103 vmnic three says

93
03:35.700 --> 03:38.040
use 103 for the transport VLAN,

94
03:38.040 --> 03:40.890
and if we scroll down, we're using vmnic three.

95
03:40.890 --> 03:42.750
Now here it's just a label in NSX,

96
03:42.750 --> 03:44.430
but we'll wanna map that over

97
03:44.430 --> 03:47.880
to the corresponding vmnic three on the respective host.

98
03:47.880 --> 03:50.520
So here for Edge-2 we're also gonna use Uplink three

99
03:50.520 --> 03:54.180
on its respective host, but we're gonna be using VLAN 104.

100
03:54.180 --> 03:57.810
So Uplink three right here and VLAN 104.

101
03:57.810 --> 04:01.110
So here in NSX manager, let's take a peek at these.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

101
03:57.810 --> 04:01.110
So here in NSX manager, let's take a peek at these.

102
04:01.110 --> 04:03.870
We're looking for VLAN 104 and vmnic three,

103
04:03.870 --> 04:06.090
and that looks, based on the title, like it might be it.

104
04:06.090 --> 04:08.100
So if we click on it to confirm, sure enough,

105
04:08.100 --> 04:10.530
that's using Transport VLAN 104.

106
04:10.530 --> 04:13.680
And the label regarding this Uplink profile says

107
04:13.680 --> 04:14.820
vmnic three.

108
04:14.820 --> 04:17.130
So we'd wanna map that correctly, this label called

109
04:17.130 --> 04:20.040
vmnic three over to the associated Uplink

110
04:20.040 --> 04:22.650
on the distributed switch that leads out to

111
04:22.650 --> 04:23.880
vmnic three physically.

112
04:23.880 --> 04:25.860
In fact, to make that a little more clear, let's go ahead

113
04:25.860 --> 04:28.380
and edit this Uplink profile.

114
04:28.380 --> 04:31.260
And instead of calling the Uplink vmnic three,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

114
04:28.380 --> 04:31.260
And instead of calling the Uplink vmnic three,

115
04:31.260 --> 04:33.686
I'll go ahead and double click here to edit it.

116
04:33.686 --> 04:37.080
Let's go ahead and call it vmnic dash T-R-E-S,

117
04:37.080 --> 04:39.060
for three in Espanol.

118
04:39.060 --> 04:40.170
And that way when we see it,

119
04:40.170 --> 04:41.880
we'll know exactly where that came from.

120
04:41.880 --> 04:43.380
It came from this Uplink profile,

121
04:43.380 --> 04:46.230
and then we'll map it to the appropriate Uplink

122
04:46.230 --> 04:47.550
over on the distributed switch.

123
04:47.550 --> 04:48.780
So we'll click on save.

124
04:48.780 --> 04:51.840
So we verified that we not only have the appropriate

125
04:51.840 --> 04:54.570
VLANs available on the physical transport network,

126
04:54.570 --> 04:56.850
but we also verified that we have appropriate

127
04:56.850 --> 04:58.830
Uplink profiles that we can use.

128
04:58.830 --> 05:00.690
This one right here for Edge-1
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

128
04:58.830 --> 05:00.690
This one right here for Edge-1

129
05:00.690 --> 05:02.550
and this one right here for Edge-2.

130
05:02.550 --> 05:05.190
So to deploy an Edge node it's super easy

131
05:05.190 --> 05:06.960
to do right here from the NSX manager.

132
05:06.960 --> 05:09.300
We simply go to system where we currently are,

133
05:09.300 --> 05:12.420
and then on the left we simply go to nodes.

134
05:12.420 --> 05:15.180
So as time goes on, they may rearrange things a little bit,

135
05:15.180 --> 05:17.490
but at the moment with the current flavor of NSX,

136
05:17.490 --> 05:18.510
it is right here.

137
05:18.510 --> 05:21.420
Now, currently it shows that we have an edge node

138
05:21.420 --> 05:24.300
called Edge-1 already in place, and I'll tell you why.

139
05:24.300 --> 05:28.260
This takes about an hour to deploy an Edge node

140
05:28.260 --> 05:30.870
and part of the time there is gonna deploy the full VM on
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

140
05:28.260 --> 05:30.870
and part of the time there is gonna deploy the full VM on

141
05:30.870 --> 05:34.380
the ESXI host, it's going to initialize that Edge node

142
05:34.380 --> 05:35.430
and then once it's up and running,

143
05:35.430 --> 05:37.020
it takes a little longer to get fully baked.

144
05:37.020 --> 05:39.420
So from start to finish, it probably takes somewhere

145
05:39.420 --> 05:43.020
between 45 minutes and an hour to deploy an Edge.

146
05:43.020 --> 05:45.120
So what I did earlier is I deployed this Edge,

147
05:45.120 --> 05:47.160
ran an errand, and then came back.

148
05:47.160 --> 05:50.520
And so Edge-1 is already in place, but have no fear,

149
05:50.520 --> 05:52.170
what we get to do is we're gonna go

150
05:52.170 --> 05:54.510
through the exact same steps, but for Edge-2,

151
05:54.510 --> 05:57.330
and that way as we wait for Edge-2 to finish,

152
05:57.330 --> 06:01.050
we can take the steps of validating our existing Edge node
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

152
05:57.330 --> 06:01.050
we can take the steps of validating our existing Edge node

153
06:01.050 --> 06:02.430
that's already in place.

154
06:02.430 --> 06:04.500
So let's go ahead and deploy Edge-2.

155
06:04.500 --> 06:06.630
And lemme go ahead and arrow this to the left a little bit

156
06:06.630 --> 06:08.700
so we can have a little more real estate right here.

157
06:08.700 --> 06:12.570
And let's click on add Edge node and let's add Edge-2.

158
06:12.570 --> 06:14.700
And just as a reminder about the details for that,

159
06:14.700 --> 06:15.840
Edge-2 is gonna have the

160
06:15.840 --> 06:19.770
management address of 192, 168, 1.192.

161
06:19.770 --> 06:21.690
We're gonna use a static configured IP address

162
06:21.690 --> 06:24.600
of 44, et cetera for the tunnel endpoint,

163
06:24.600 --> 06:27.480
we'll use Uplink three over here on ESXIB

164
06:27.480 --> 06:30.540
and we'll use VLAN 104 for the transport VLAN.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

164
06:27.480 --> 06:30.540
and we'll use VLAN 104 for the transport VLAN.

165
06:30.540 --> 06:31.890
So with that in mind, let's go back

166
06:31.890 --> 06:33.870
and do the deployment of Edge-2.

167
06:33.870 --> 06:35.850
So we'll go ahead and call this Edge-2,

168
06:35.850 --> 06:38.640
and then it's asking for a fully qualified domain name.

169
06:38.640 --> 06:42.120
So let me also verify I've got that set up in DNS.

170
06:42.120 --> 06:44.010
So here is a command prompt,

171
06:44.010 --> 06:46.080
and I'm gonna be using my lab DNS server,

172
06:46.080 --> 06:47.130
which is at dot 100,

173
06:47.130 --> 06:49.110
so we'll go ahead and do an NS lookup.

174
06:49.110 --> 06:49.943
And there we go.

175
06:49.943 --> 06:52.080
We're using the DNS server, the same one I'm gonna be

176
06:52.080 --> 06:53.910
telling this Edge node to use.

177
06:53.910 --> 06:57.720
And lemme do a lookup for Edge-2.OGIT.local,

178
06:57.720 --> 06:58.553
and press enter.

179
06:58.553 --> 07:01.320
And sure enough, it does have a record there.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

179
06:58.553 --> 07:01.320
And sure enough, it does have a record there.

180
07:01.320 --> 07:02.790
And let's also do a reverse lookup

181
07:02.790 --> 07:07.680
by putting in net address 192.168.1.192 and pressing enter.

182
07:07.680 --> 07:09.810
So both forward and reverse look-ups are working.

183
07:09.810 --> 07:10.920
That's fantastic.

184
07:10.920 --> 07:14.400
So that's the name we're gonna use: Edge-2.OGIT.Local.

185
07:14.400 --> 07:16.230
So I'm gonna highlight that, press enter to copy it

186
07:16.230 --> 07:18.150
to my buffer and then go back here,

187
07:18.150 --> 07:20.790
right click and simply paste it in.

188
07:20.790 --> 07:22.530
Next, it's asking this for the form factor.

189
07:22.530 --> 07:25.050
This is a question about how many resources do we wanna

190
07:25.050 --> 07:27.720
throw at this Edge VM?

191
07:27.720 --> 07:29.640
And so I'm gonna go ahead and choose medium,

192
07:29.640 --> 07:31.920
which will chew up four CPUs and eight gigabytes of RAM.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

192
07:29.640 --> 07:31.920
which will chew up four CPUs and eight gigabytes of RAM.

193
07:31.920 --> 07:34.680
But just be aware, especially in the lab environment,

194
07:34.680 --> 07:38.370
that by default it's gonna take all the RAM that you give it

195
07:38.370 --> 07:41.700
as a guarantee, meaning there's gonna be a reservation.

196
07:41.700 --> 07:43.140
So if we scroll down a little bit,

197
07:43.140 --> 07:46.050
instead of saying a hundred percent memory reservation,

198
07:46.050 --> 07:48.120
I'm gonna cut that back to 50.

199
07:48.120 --> 07:49.890
And that way if push comes to shove,

200
07:49.890 --> 07:52.770
I can still bring up this Edge VM,

201
07:52.770 --> 07:55.710
even if there isn't a full quantity of RAM

202
07:55.710 --> 07:57.150
that I can allocate to it based on

203
07:57.150 --> 07:59.010
other resources needing that memory.

204
07:59.010 --> 08:02.490
So I'm gonna just set it up to reserve 50% of that RAM,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

204
07:59.010 --> 08:02.490
So I'm gonna just set it up to reserve 50% of that RAM,

205
08:02.490 --> 08:04.110
but I'm gonna go for the medium size

206
08:04.110 --> 08:05.430
and click on "next".

207
08:05.430 --> 08:08.250
I'll go ahead and supply a password for admin

208
08:08.250 --> 08:09.210
and also for root.

209
08:09.210 --> 08:12.750
I'm also gonna say I want to allow SSH logins.

210
08:12.750 --> 08:15.480
So those passwords have been supplied and confirmed.

211
08:15.480 --> 08:17.550
We'll scroll down and I'm not too worried about,

212
08:17.550 --> 08:18.930
for my lab, the audit credentials,

213
08:18.930 --> 08:21.390
so I'm gonna leave those blank and click on "next".

214
08:21.390 --> 08:22.860
Now it's asking me about where do you want

215
08:22.860 --> 08:24.030
to deploy this VM?

216
08:24.030 --> 08:28.470
So based on our plan, Edge-2 is gonna be placed on ESXIB,

217
08:28.470 --> 08:30.900
which is under the control of vCenter,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

217
08:28.470 --> 08:30.900
which is under the control of vCenter,

218
08:30.900 --> 08:33.630
the vCenter that we identified in NSX manager

219
08:33.630 --> 08:34.950
as our vCenter.

220
08:34.950 --> 08:37.770
And then as far as which cluster is that ESXI host in,

221
08:37.770 --> 08:40.380
it's in the host transport nodes.

222
08:40.380 --> 08:42.270
And then I don't have a specific resource pool

223
08:42.270 --> 08:44.490
that I wanna put 'em in, but I do wanna specify the host.

224
08:44.490 --> 08:46.170
And so I am gonna choose the host

225
08:46.170 --> 08:49.260
and we're gonna choose ESXIB based on our plan.

226
08:49.260 --> 08:52.170
And then for the data store for this little VM,

227
08:52.170 --> 08:54.750
I'm gonna choose the local data store on ESXIB,

228
08:54.750 --> 08:56.010
and then we'll click on "next".

229
08:56.010 --> 08:59.400
Now it's asking about the management interface for Edge-2.

230
08:59.400 --> 09:01.770
So let's take a look at our plan once again.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

230
08:59.400 --> 09:01.770
So let's take a look at our plan once again.

231
09:01.770 --> 09:05.610
So in our plan we wanna use 192, 168, 1.192

232
09:05.610 --> 09:08.760
with a 24 bit mask as the management IP address.

233
09:08.760 --> 09:10.320
So we'll put that in next.

234
09:10.320 --> 09:12.060
So we'll click here to say that we want

235
09:12.060 --> 09:13.950
to have a statically assigned IP address,

236
09:13.950 --> 09:17.730
and we'll use the address of 192.168.1.1.92

237
09:17.730 --> 09:19.260
with a 24 bit mask.

238
09:19.260 --> 09:20.610
And it wants the default gateway,

239
09:20.610 --> 09:23.250
so in my lab environment on my management network,

240
09:23.250 --> 09:26.130
it is 192.168.1.1.

241
09:26.130 --> 09:29.120
And now it's asking me for which interface do we wanna use

242
09:29.120 --> 09:30.600
for the management network?
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

242
09:29.120 --> 09:30.600
for the management network?

243
09:30.600 --> 09:32.040
So we're gonna select a port group.

244
09:32.040 --> 09:34.080
So here is a port group that leads off

245
09:34.080 --> 09:35.070
to my management network.

246
09:35.070 --> 09:38.430
So I'm gonna choose that for the connection for this VM

247
09:38.430 --> 09:40.140
to connect to the management network.

248
09:40.140 --> 09:41.520
And we'll click on "save".

249
09:41.520 --> 09:45.030
And then for the search domains, I'm in the OGIT.local,

250
09:45.030 --> 09:46.440
and then the DNS servers can be my

251
09:46.440 --> 09:49.830
Windows server at 192.168.1.100.

252
09:49.830 --> 09:54.090
And the same Windows server at 192.168.1.100

253
09:54.090 --> 09:57.570
is acting as a network time protocol server, as well.

254
09:57.570 --> 10:00.630
And then down here it's asking if we want to enable UPT mode
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

254
09:57.570 --> 10:00.630
And then down here it's asking if we want to enable UPT mode

255
10:00.630 --> 10:02.640
and I don't have the Smartnicks to support that,

256
10:02.640 --> 10:04.110
so I'm gonna go ahead and leave that off,

257
10:04.110 --> 10:05.970
and then we'll click on "next" to continue.

258
10:05.970 --> 10:08.340
So NSX has been through several iterations

259
10:08.340 --> 10:10.950
and several versions like two and two x and three

260
10:10.950 --> 10:12.330
and three x, and now we're at four.

261
10:12.330 --> 10:15.570
And currently we're at 4.1.1 as of this recording.

262
10:15.570 --> 10:17.250
So as far as the Edge Switch name,

263
10:17.250 --> 10:18.600
we don't have to deal with that anymore,

264
10:18.600 --> 10:20.070
we can just leave that as the default.

265
10:20.070 --> 10:22.830
And then now we're gonna specify which transport zones we

266
10:22.830 --> 10:24.660
want this Edge to be able to support.

267
10:24.660 --> 10:27.090
So again, the transport zone is like the range of

268
10:27.090 --> 10:28.890
how far a segment can go.

269
10:28.890 --> 10:32.910
So currently, everywhere else, our host transport nodes
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

269
10:28.890 --> 10:32.910
So currently, everywhere else, our host transport nodes

270
10:32.910 --> 10:36.090
and also Edge-1, which I already deployed, I specified

271
10:36.090 --> 10:39.420
that I just wanna support at the moment one transport zone,

272
10:39.420 --> 10:41.610
and that's the one we created a few skills go,

273
10:41.610 --> 10:44.100
that's our AB overlay transport zone.

274
10:44.100 --> 10:45.150
And so we can add more later,

275
10:45.150 --> 10:48.420
but at the moment I just want this one Edge, Edge-2

276
10:48.420 --> 10:50.250
to be able to support any segments in

277
10:50.250 --> 10:51.900
that overlay transport zone.

278
10:51.900 --> 10:54.900
And next it's asking us about the Uplink profile.

279
10:54.900 --> 10:56.460
And so we already confirmed earlier

280
10:56.460 --> 10:58.500
that we have an Uplink profile that we can use.

281
10:58.500 --> 11:00.750
And based on our plan, we want the Uplink profile
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

281
10:58.500 --> 11:00.750
And based on our plan, we want the Uplink profile

282
11:00.750 --> 11:03.120
that's gonna support Uplink three here on

283
11:03.120 --> 11:06.470
ESXIB once it gets deployed, and VLAN 104.

284
11:06.470 --> 11:08.910
So we'll grab the appropriate Uplink profile

285
11:08.910 --> 11:10.350
that does exactly that.

286
11:10.350 --> 11:15.350
So we'll use the dropdown and we want VLAN 104

287
11:15.360 --> 11:17.490
and Uplink three, and so we're gonna grab

288
11:17.490 --> 11:18.930
that one right there.

289
11:18.930 --> 11:20.520
So there's our Uplink profile

290
11:20.520 --> 11:22.110
and as a result of that, it's now asking us

291
11:22.110 --> 11:25.050
to map over the label that we put associated

292
11:25.050 --> 11:26.100
with that Uplink profile.

293
11:26.100 --> 11:29.040
There it is, vmnic-tres, and then map it over

294
11:29.040 --> 11:32.070
to an actual port group on a distributed switch.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

294
11:29.040 --> 11:32.070
to an actual port group on a distributed switch.

295
11:32.070 --> 11:33.480
So currently on the distributed switch,

296
11:33.480 --> 11:37.830
I currently have a port group called this: "DPG leads

297
11:37.830 --> 11:39.300
to vmnic3".

298
11:39.300 --> 11:40.980
In fact, let's pause for just a moment

299
11:40.980 --> 11:44.220
and make a road trip over to the vSphere Client.

300
11:44.220 --> 11:46.170
And let me show you that port group.

301
11:46.170 --> 11:47.520
So here on the vSphere Client,

302
11:47.520 --> 11:49.320
if we go to the network tab here,

303
11:49.320 --> 11:52.170
and then we open up this DS for NSX,

304
11:52.170 --> 11:53.280
I have this port group.

305
11:53.280 --> 11:54.240
Notice there's no end there,

306
11:54.240 --> 11:56.760
this is just a normal distributed switch port group

307
11:56.760 --> 11:59.310
that's available to both ESXIA and B.

308
11:59.310 --> 12:00.960
And if you look at the properties of this,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

308
11:59.310 --> 12:00.960
And if you look at the properties of this,

309
12:00.960 --> 12:03.870
right click and click on "edit settings",

310
12:03.870 --> 12:06.510
and then I'll take you down to teaming and failover.

311
12:06.510 --> 12:09.270
So as part of this pork group called "DPG leads

312
12:09.270 --> 12:12.150
to vmnic3", the only active Uplink we're using

313
12:12.150 --> 12:13.140
is vmnic three.

314
12:13.140 --> 12:15.570
So you certainly could add in additional fault tolerance

315
12:15.570 --> 12:18.180
with standby links, or if you wanna have two taps,

316
12:18.180 --> 12:20.520
you could go ahead and do two active Uplinks,

317
12:20.520 --> 12:21.930
based on the Uplink profile you're using.

318
12:21.930 --> 12:23.490
But I just wanna verify and show you

319
12:23.490 --> 12:27.090
that this port group called "DPG leads to vmnic3"

320
12:27.090 --> 12:30.420
is only using the Uplink vmnic three on
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

320
12:27.090 --> 12:30.420
is only using the Uplink vmnic three on

321
12:30.420 --> 12:32.160
the respective host that it's currently running on.

322
12:32.160 --> 12:33.720
So I'll click on "cancel".

323
12:33.720 --> 12:36.210
We could also go ahead and click on the parent switch here,

324
12:36.210 --> 12:37.500
this distributed switch,

325
12:37.500 --> 12:39.990
and click on "configure" and go to "topology",

326
12:39.990 --> 12:41.670
and that would also show us the story there.

327
12:41.670 --> 12:46.350
So this port group right here only uses vmnic three,

328
12:46.350 --> 12:47.790
and that's what this represents.

329
12:47.790 --> 12:50.250
And there's Edge-1 that I deployed earlier today

330
12:50.250 --> 12:52.140
and we're about to deploy Edge-2,

331
12:52.140 --> 12:54.600
which will also be using this port group

332
12:54.600 --> 12:56.130
for its transport network.

333
12:56.130 --> 13:00.540
Except, unlike Edge-1, Edge-2 is gonna be using VLAN 104
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

333
12:56.130 --> 13:00.540
Except, unlike Edge-1, Edge-2 is gonna be using VLAN 104

334
13:00.540 --> 13:03.390
and Edge-1 is using VLAN 103

335
13:03.390 --> 13:05.340
as it communicates over the transport network.

336
13:05.340 --> 13:08.070
And again, you can use the same exact VLAN if you want to,

337
13:08.070 --> 13:09.360
the same exact subnet,

338
13:09.360 --> 13:11.070
but for the purpose of education and learning,

339
13:11.070 --> 13:13.290
I thought having completely separate

340
13:13.290 --> 13:16.170
IP addresses and separate ranges is gonna make it more clear

341
13:16.170 --> 13:18.030
about which end of the tunnel goes where.

342
13:18.030 --> 13:21.990
Alright, so back at the NSX deployment of Edge-2,

343
13:21.990 --> 13:24.690
we're gonna choose "DPG leads to vmnic3"

344
13:24.690 --> 13:27.720
as the port group that uses vmnic three that we wanna use.

345
13:27.720 --> 13:29.040
We'll click on "save" there.

346
13:29.040 --> 13:30.570
And now it's asking us about the assignment
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

346
13:29.040 --> 13:30.570
And now it's asking us about the assignment

347
13:30.570 --> 13:32.970
of the IP address for the tunnel endpoint.

348
13:32.970 --> 13:35.640
So we're gonna go ahead and use a static IP list

349
13:35.640 --> 13:37.440
and then we'll scroll down and go ahead and put that in.

350
13:37.440 --> 13:40.650
And that's gonna be 44.44.44.44.

351
13:40.650 --> 13:43.470
And the default gateway is my top of rack switch

352
13:43.470 --> 13:45.150
or the top of rack infrastructure,

353
13:45.150 --> 13:47.490
which is 44.44.44.1,

354
13:47.490 --> 13:50.130
we looked at that earlier, verified that was in place.

355
13:50.130 --> 13:51.540
And we're using a 24 bit mask,

356
13:51.540 --> 13:53.040
so we'll put that in, as well.

357
13:53.040 --> 13:56.370
And I think we have specified all the details here

358
13:56.370 --> 13:57.720
that we need to for Edge-2.

359
13:57.720 --> 14:02.070
So we'll click on "finish" and it is on its way.
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

359
13:57.720 --> 14:02.070
So we'll click on "finish" and it is on its way.

360
14:02.070 --> 14:03.520
So lemme manage the columns a little bit right here.

361
14:03.520 --> 14:05.940
Lemme go ahead and remove ID for a moment

362
14:05.940 --> 14:07.380
and the deployment type,

363
14:07.380 --> 14:09.660
and the management IP address, I'll remove.

364
14:09.660 --> 14:11.670
And the host that's running on, I'll remove.

365
14:11.670 --> 14:13.230
And I'll leave everything else

366
14:13.230 --> 14:15.330
and that'll make it just a little bit easier to read.

367
14:15.330 --> 14:18.120
So this Edge-2, which is now being deployed, again,

368
14:18.120 --> 14:20.250
this takes somewhere between 45 minutes

369
14:20.250 --> 14:22.590
and an hour to complete.

370
14:22.590 --> 14:24.000
So here on the vSphere Client,

371
14:24.000 --> 14:27.690
if we look at the tasks, it's now doing the deployment of

372
14:27.690 --> 14:30.360
that OVF template, effectively Edge-2,
WEBVTT
X-TIMESTAMP-MAP=LOCAL:00:00:00.000,MPEGTS:900000

372
14:27.690 --> 14:30.360
that OVF template, effectively Edge-2,

373
14:30.360 --> 14:33.450
and it's deploying it now over on ESXIB.

374
14:33.450 --> 14:36.510
So if we went over to the VM and templates view,

375
14:36.510 --> 14:38.436
down here we have Edge-1 on it,

376
14:38.436 --> 14:39.269
that's the one I deployed earlier,

377
14:39.269 --> 14:40.530
and I'm just gonna drag and drop that

378
14:40.530 --> 14:44.040
into the folder called "Edge Node VMs" right there

379
14:44.040 --> 14:46.590
and then Edge-2, I'm not gonna try to move that

380
14:46.590 --> 14:49.230
until it is completely deployed.

381
14:49.230 --> 14:50.340
So I'm gonna go ahead and give

382
14:50.340 --> 14:53.430
that deployment probably another 45 minutes to an hour

383
14:53.430 --> 14:55.053
to go ahead and finish.
