00:00:00.000 --> 00:00:07.000
Welcome back to BSphere 8 in the real world. Now we'll discuss connecting to storage.

00:00:07.000 --> 00:00:11.000
So, in order to connect to storage, you're going to need a storage adapter.

00:00:11.000 --> 00:00:15.000
If you're trying to connect to local storage, you'll have a storage controller, you know,

00:00:15.000 --> 00:00:19.000
in that server that connects you to those disks and that's how you're connecting to your storage.

00:00:19.000 --> 00:00:24.000
If you're using a SAN, you're going to have an HBA.

00:00:24.000 --> 00:00:27.000
You might have an iSCSI HBA. You might have a fiber channel HBA.

00:00:27.000 --> 00:00:34.000
You might have a software, what's called a software initiator or a software, you know, basically HBA.

00:00:34.000 --> 00:00:41.000
So, you can have a software iSCSI initiator or you can have a software fiber channel over Ethernet initiator.

00:00:41.000 --> 00:00:48.000
So, a SCSI adapter would just be an adapter in the system in your server that, you know,

00:00:48.000 --> 00:00:55.000
cables connecting to drives and using SCSI commands from this card over those cables to those drives that are in that server.

00:00:55.000 --> 00:01:04.000
iSCSI is sending SCSI commands, again, to drives, but now we're encapsulating those SCSI commands in IP

00:01:04.000 --> 00:01:07.000
and then we're sending them over a network.

00:01:07.000 --> 00:01:14.000
Now, if we have an HBA, what that means is we have a card that is, you know, an intelligent card, a smart card,

00:01:14.000 --> 00:01:17.000
that has a chip on it that knows how to speak iSCSI.

00:01:17.000 --> 00:01:25.000
So, the iSCSI host can take that workload, offload it to the HBA, and let the HBA manage all the IP stuff,

00:01:25.000 --> 00:01:30.000
all the, you know, all the checks on the disk and, you know, putting the encapsulation on there

00:01:30.000 --> 00:01:32.000
and sending it out over the network.

00:01:32.000 --> 00:01:37.000
And then when it comes back in, again, the card can check the packets, make sure that they're valid, you know,

00:01:37.000 --> 00:01:44.000
remove all the IP and just send the operating system SCSI instead of having to always have to do all that IP work as well.

00:01:45.000 --> 00:01:51.000
iSCSI HBAs are not really as common as you might think.

00:01:51.000 --> 00:01:57.000
A lot of times if you're doing iSCSI, it's because you're trying to do less expensive than fiber channel.

00:01:57.000 --> 00:02:01.000
And a lot of times if you're doing iSCSI are using what's called a software initiator,

00:02:01.000 --> 00:02:05.000
which means they have like a 10-gig NIC in their system, but it's just a regular NIC.

00:02:05.000 --> 00:02:06.000
It's not an HBA.

00:02:06.000 --> 00:02:09.000
It's not a smart card necessarily.

00:02:09.000 --> 00:02:11.000
And the kernel is doing a lot of that work.

00:02:11.000 --> 00:02:17.000
Back when processors were slower, you could see a huge improvement by having iSCSI HBA,

00:02:17.000 --> 00:02:24.000
like maybe like 30 or so percent improvement in performance and a huge reduction in CPU utilization.

00:02:24.000 --> 00:02:29.000
With CPUs being so much faster than they used to be, and, you know, networks are still very fast.

00:02:29.000 --> 00:02:31.000
They're only getting faster.

00:02:31.000 --> 00:02:37.000
You're seeing more and more people being willing to take a smaller performance hit and save the money from the HBA.

00:02:38.000 --> 00:02:44.000
But there are also more and more people who are starting to buy these smart adapters,

00:02:44.000 --> 00:02:48.000
and the smart adapters can handle things on the card kind of in a flexible way.

00:02:48.000 --> 00:02:54.000
You can say I want this card to be an iSCSI initiator and offload the work to there or a function over Ethernet initiator.

00:02:54.000 --> 00:02:58.000
Or what you can do is say this card's got four ports.

00:02:58.000 --> 00:03:04.000
I want two of them to be regular IP ports and two of them to be iSCSI HBA ports and, you know, things like that.

00:03:04.000 --> 00:03:11.000
So there's a lot of different things happening, and which is going to be the trend in the future, who knows.

00:03:11.000 --> 00:03:14.000
For a while it was starting to go more and more just regular software initiator,

00:03:14.000 --> 00:03:18.000
but now you're starting to see these specialty cards becoming more popular.

00:03:18.000 --> 00:03:21.000
They get more functionality and become less expensive too.

00:03:21.000 --> 00:03:25.000
So RAID, there are RAID controllers.

00:03:25.000 --> 00:03:29.000
So a SCSI adapter just shows each disk to the operating system.

00:03:29.000 --> 00:03:34.000
If there are seven disks attached to a SCSI controller, the operating system sees seven disks.

00:03:34.000 --> 00:03:39.000
A RAID controller has the ability to take those seven disks, and you can log into the card,

00:03:39.000 --> 00:03:48.000
and you can say I want to create a RAID 0 or a RAID 1 or a RAID 6 or whatever it is you want to configure with these seven disks,

00:03:48.000 --> 00:03:54.000
and then they present to the operating system those seven disks as one disk.

00:03:54.000 --> 00:04:00.000
On your ESXi host, if you're not using vSAN, then it's fine to configure RAID on them.

00:04:00.000 --> 00:04:03.000
Local disks aren't used a lot either way.

00:04:03.000 --> 00:04:09.000
If you're not using vSANs on your host, maybe you're just using it for storing ISOs or something like that on them maybe.

00:04:09.000 --> 00:04:16.000
If you're using vSAN, then you don't want any RAID configured on those disks.

00:04:16.000 --> 00:04:22.000
You want each disk presented to the ESXi host as the disk they actually are.

00:04:22.000 --> 00:04:26.000
So, a lot of RAID controllers now have the ability to be a RAID controller,

00:04:26.000 --> 00:04:35.000
or you can flip them and say just be a basically a SCSI adapter and show every disk on this controller to the operating system,

00:04:35.000 --> 00:04:40.000
and that is primarily there for the benefit of ESXi and vSAN.

00:04:40.000 --> 00:04:46.000
So, fiber. Fiber means you are using glass instead of copper for your cabling.

00:04:46.000 --> 00:04:54.000
There's fiber channel. Fiber channel is a network protocol where obviously we're expecting to see fiber glass,

00:04:54.000 --> 00:05:00.000
and we have fiber channel HBAs, and you have to have a fiber channel HBA to use fiber channel.

00:05:00.000 --> 00:05:07.000
And we're sending the SCSI packets encapsulated in fiber channel out over my network,

00:05:07.000 --> 00:05:13.000
either from the storage array or the ESXi host to the storage array of the ESXi host,

00:05:13.000 --> 00:05:16.000
meaning that the cable goes straight from the SAN to the host.

00:05:16.000 --> 00:05:19.000
There's nothing in between, and they're so directly attached.

00:05:19.000 --> 00:05:23.000
Or it could also go to a fiber channel switch.

00:05:23.000 --> 00:05:27.000
So, in that situation, we might have a switch with, you know, 48 ports.

00:05:27.000 --> 00:05:32.000
We have a stack of 48-port fiber channel switches, and the SANs,

00:05:32.000 --> 00:05:36.000
and maybe multiple SANs are connected to that switch, and my host,

00:05:36.000 --> 00:05:39.000
and maybe I've got a lot of hosts are connected to those switches,

00:05:40.000 --> 00:05:47.000
and I can do what's called zoning on the switches and say these particular hosts are able to see these SANs.

00:05:47.000 --> 00:05:51.000
Or I can even say as far down as these LUNs on these SANs through my zoning.

00:05:51.000 --> 00:05:52.000
All right?

00:05:52.000 --> 00:05:58.000
So, if I have a lot of hosts, more than I could plug into a storage array,

00:05:58.000 --> 00:06:04.000
and maybe have multiple storage arrays, and so, again, you know, more than one host could connect to,

00:06:04.000 --> 00:06:07.000
I'll create a fiber – or use a fiber channel switch.

00:06:07.000 --> 00:06:11.000
Now, fiber channel over Ethernet means I'm using an Ethernet switch.

00:06:11.000 --> 00:06:20.000
So, I'm encapsulating my iSCSI traffic in fiber channel in Ethernet and sending it over the network.

00:06:20.000 --> 00:06:22.000
And it's just a regular Ethernet network.

00:06:22.000 --> 00:06:23.000
It could still be glass.

00:06:23.000 --> 00:06:24.000
It doesn't have to be copper.

00:06:24.000 --> 00:06:26.000
A lot of people associate Ethernet with copper.

00:06:26.000 --> 00:06:31.000
But you can also send Ethernet packets over fiber optic cables.

00:06:31.000 --> 00:06:36.000
So, maybe I have fiber cables connecting my hosts directly into my storage array,

00:06:36.000 --> 00:06:39.000
and I'm just using fiber channel over Ethernet between them.

00:06:39.000 --> 00:06:47.000
Because I'm using Ethernet cards that are just Ethernet cards with fiber, you know, SFP ports on them.

00:06:47.000 --> 00:06:51.000
And then Ethernet is just an encapsulation protocol, right?

00:06:51.000 --> 00:06:56.000
Just a way – it's a protocol that works at Layer 2 to get, you know, packets onto the wire.

00:06:56.000 --> 00:07:00.000
This is how the wire, you know, the Layer 2 part of the network is going to be working.

00:07:00.000 --> 00:07:05.000
Above that is, you know, things like IT for addressing and routing.

00:07:05.000 --> 00:07:09.000
Layer 2 Ethernet also has MAC addresses for addressing.

00:07:09.000 --> 00:07:11.000
But it's a hardware address.

00:07:11.000 --> 00:07:12.000
Above that, IP.

00:07:12.000 --> 00:07:19.000
That's where you start, you know, like operating system and operating system addresses and stuff like that.

00:07:19.000 --> 00:07:21.000
So, SAM implementations.

00:07:21.000 --> 00:07:22.000
There's fiber channel SAMs.

00:07:22.000 --> 00:07:24.000
There's fiber channel over Ethernet SAMs.

00:07:24.000 --> 00:07:26.000
And there's iSCSI SAMs, right?

00:07:26.000 --> 00:07:30.000
So, you will need to set up those SAMs.

00:07:30.000 --> 00:07:33.000
And each type of SAM will be set up differently.

00:07:33.000 --> 00:07:36.000
Every vendor with a different type of SAM will be set up differently.

00:07:36.000 --> 00:07:43.000
So, you may have a fiber channel SAM from one vendor and you set it up a little differently than you might a fiber channel SAM from a different vendor.

00:07:43.000 --> 00:07:44.000
Same thing with iSCSI.

00:07:44.000 --> 00:07:49.000
There are certain things that will be the same, though, across all of them, for example, if it's fiber channels.

00:07:49.000 --> 00:07:53.000
So, for example, fiber channels devices all have unique worldwide names.

00:07:53.000 --> 00:07:59.000
So, there's going to be the worldwide name for the initiator on the host.

00:07:59.000 --> 00:08:01.000
And there's going to be a worldwide name for the SAM.

00:08:01.000 --> 00:08:07.000
And each storage controller on the SAM is going to have a unique worldwide name.

00:08:07.000 --> 00:08:08.000
All right?

00:08:08.000 --> 00:08:12.000
So, you know, things like that are going to be the same across all fiber channel vendors.

00:08:12.000 --> 00:08:16.000
So, there might be uniquenesses within how you configure the disk and the LUNs and all that kind of stuff,

00:08:16.000 --> 00:08:21.000
but certain things are always going to be the same, like, for example, using worldwide names for fiber channel.

00:08:21.000 --> 00:08:23.000
Okay?

00:08:23.000 --> 00:08:26.000
The SAM admin can't access the OS of the VMs.

00:08:26.000 --> 00:08:31.000
So, you know, the VMs themselves are not accessible from the SAM.

00:08:31.000 --> 00:08:33.000
What's on those disks may be.

00:08:33.000 --> 00:08:34.000
Right?

00:08:34.000 --> 00:08:37.000
That kind of depends on how you are implementing it.

00:08:37.000 --> 00:08:42.000
If you're implementing on your ESXi host and your vSphere environments encryption, then it's encrypted on there, too.

00:08:42.000 --> 00:08:44.000
So, it's not going to be accessible.

00:08:44.000 --> 00:08:45.000
All right?

00:08:45.000 --> 00:08:47.000
But it can monitor what's happening.

00:08:47.000 --> 00:08:48.000
Okay?

00:08:48.000 --> 00:08:49.000
It doesn't see the data that's going on.

00:08:49.000 --> 00:08:51.000
It can't see what's going on with the VMs themselves.

00:08:51.000 --> 00:08:52.000
But it can monitor the storage.

00:08:52.000 --> 00:08:54.000
It can see things like latency.

00:08:54.000 --> 00:08:58.000
It can see things like if there's errors in the packets coming in and things like that.

00:08:58.000 --> 00:08:59.000
Okay?

00:08:59.000 --> 00:09:03.000
The HBA is visible to the SAM as being part of the ESXi system.

00:09:03.000 --> 00:09:08.000
The HBA is not visible to the SAM to show them the VM.

00:09:08.000 --> 00:09:09.000
Okay?

00:09:09.000 --> 00:09:10.000
The SAM doesn't see the VM.

00:09:10.000 --> 00:09:11.000
It sees the ESXi host.

00:09:11.000 --> 00:09:13.000
The ESXi host is writing that data.

00:09:13.000 --> 00:09:18.000
The only time that might be different is if you had a physical mode raw device map.

00:09:18.000 --> 00:09:19.000
Okay?

00:09:19.000 --> 00:09:21.000
ESXi performs the multipathing.

00:09:21.000 --> 00:09:26.000
So, ESXi will decide how packets get from it and, you know, if it's going to do round-robin

00:09:26.000 --> 00:09:28.000
or what's going to happen there to the SAM.

00:09:28.000 --> 00:09:30.000
The SAM doesn't decide that.

00:09:30.000 --> 00:09:35.000
The ESXi host decides what kind of multipathing scheme they're going to use.

00:09:35.000 --> 00:09:40.000
So, to do a SAM setup, generally, there's a few things you're going to need to do.

00:09:40.000 --> 00:09:45.000
So, on the ESXi host, you're going to need to make sure that it has – is available

00:09:45.000 --> 00:09:46.000
to see the SAM.

00:09:46.000 --> 00:09:50.000
So, you're going to need to make sure that on the ESXi host, you have the HBA.

00:09:50.000 --> 00:09:52.000
You have the HBA configured correctly.

00:09:52.000 --> 00:09:56.000
It knows the address that's on the – you know, for the zoning or whatever you're going

00:09:56.000 --> 00:09:57.000
to be doing.

00:09:57.000 --> 00:09:58.000
For the SAM, it is ISCSI.

00:09:58.000 --> 00:10:02.000
It needs to know the IP address of the SAM that you're connecting to.

00:10:02.000 --> 00:10:06.000
Then you're going to provide the host with a worldwide name.

00:10:06.000 --> 00:10:10.000
This is for Fiber Channel, right, of the port you want to connect to.

00:10:10.000 --> 00:10:14.000
Record the worldwide names for the storage processors, which are going to be the storage

00:10:14.000 --> 00:10:17.000
controllers on the SAM itself.

00:10:17.000 --> 00:10:23.000
Then you're going to create LUNs, and you're going to assign what hosts are allowed to

00:10:23.000 --> 00:10:24.000
connect to those LUNs.

00:10:24.000 --> 00:10:28.000
On the storage device side, you're going to say what you can and cannot connect to.

00:10:28.000 --> 00:10:29.000
All right?

00:10:31.000 --> 00:10:34.000
So, templates are pre-Version 8.

00:10:34.000 --> 00:10:40.000
So, SAMs support one VMF volume per LUN.

00:10:40.000 --> 00:10:42.000
Now, you can do more.

00:10:42.000 --> 00:10:46.000
It's not recommended to do more, but, you know, people are going to sometimes do what

00:10:46.000 --> 00:10:47.000
they can do because they can.

00:10:47.000 --> 00:10:51.000
But you should create, you know, one VMF volume per LUN.

00:10:51.000 --> 00:10:57.000
Avoid diagnostic partitions on the SAM unless it's needed for, you know, the SAM vendor

00:10:57.000 --> 00:10:58.000
or something like that.

00:10:58.000 --> 00:11:02.000
So, you can create little partitions on LUNs that the SAM uses for diagnostic stuff.

00:11:02.000 --> 00:11:05.000
Try to avoid those on LUNs that are presented to your ISCSI hosts, right?

00:11:05.000 --> 00:11:08.000
Raw device maps to access raw disks.

00:11:08.000 --> 00:11:12.000
LUN ID must be consistent when presented to the ISCSI host.

00:11:12.000 --> 00:11:17.000
What they're saying is you don't want the ISCSI host to see different LUN IDs for different

00:11:17.000 --> 00:11:18.000
hosts.

00:11:18.000 --> 00:11:23.000
You want to make sure that LUN 0, LUN 1, LUN 2 are always the same on each host.

00:11:23.000 --> 00:11:29.000
LUN 2 on one host is LUN 2 on all the hosts in a cluster because you don't want the different

00:11:29.000 --> 00:11:33.000
hosts to think there is a different LUN and that VM that's running on it is a different

00:11:33.000 --> 00:11:34.000
VM.

00:11:34.000 --> 00:11:37.000
You want to be able to find the VM when it goes to look for it in case it needs to start

00:11:37.000 --> 00:11:39.000
it up or something like that, right?

00:11:40.000 --> 00:11:43.000
Ensure appropriate queues on the physical HBA.

00:11:43.000 --> 00:11:47.000
So, HBA queues are kind of an interesting thing.

00:11:47.000 --> 00:11:51.000
By default, the default HBA queue size is going to be 32.

00:11:51.000 --> 00:11:55.000
And if you don't have anything else running, nothing else has changed, it's just going

00:11:55.000 --> 00:11:56.000
to be 32.

00:11:56.000 --> 00:12:01.000
And when that queue starts to get full, then what happens is the host has to tell the SAM

00:12:01.000 --> 00:12:02.000
to back off.

00:12:02.000 --> 00:12:06.000
It has to slow down what it's sending and tell the SAM to slow down what it's sending

00:12:06.000 --> 00:12:08.000
to it, what it's receiving.

00:12:09.000 --> 00:12:11.000
And that can hinder performance.

00:12:12.000 --> 00:12:15.000
What can happen, though, is we do have something called Storage I.O.

00:12:15.000 --> 00:12:16.000
Control.

00:12:16.000 --> 00:12:17.000
And Storage I.O.

00:12:17.000 --> 00:12:26.000
Control is a way for the GIGSXI host to give certain VMs on a datastore more or less access

00:12:26.000 --> 00:12:29.000
to the datastore compared to other VMs on that same datastore.

00:12:29.000 --> 00:12:34.000
It can't make the throughput more, but it can basically control how much access to a

00:12:34.000 --> 00:12:37.000
datastore a certain VM gets compared to another one.

00:12:37.000 --> 00:12:43.000
So if one VM is really noisy, you can give one of the ones that are getting choked out

00:12:43.000 --> 00:12:44.000
some access.

00:12:44.000 --> 00:12:48.000
You can also, just based on priority, this one's just more important, so I want to give

00:12:48.000 --> 00:12:49.000
it more access.

00:12:49.000 --> 00:12:54.000
And the way the GIGSXI host does that is it actually changes that queue size.

00:12:54.000 --> 00:12:55.000
It's called queue depth.

00:12:55.000 --> 00:13:02.000
It changes the queue depth dynamically when there's contention, when there's a slowdown

00:13:02.000 --> 00:13:05.000
performance and you set that, like how many milliseconds we're going to allow for this

00:13:05.000 --> 00:13:06.000
latency.

00:13:06.000 --> 00:13:11.000
When you start to see latencies creeping up, then it will start changing the queue depth

00:13:11.000 --> 00:13:14.000
to make sure that certain VMs that need more performance get that performance.

00:13:14.000 --> 00:13:17.000
So the HPA queue is a pretty interesting thing.

00:13:17.000 --> 00:13:22.000
Windows VMs require increased SCSI timeout value to 60.

00:13:22.000 --> 00:13:26.000
So on the Windows VM itself, you're going to go in there and edit at the registry and

00:13:26.000 --> 00:13:28.000
change that timeout value to 60.

00:13:28.000 --> 00:13:33.000
And that's important because if a path were to fail and the host is trying to fail over

00:13:33.000 --> 00:13:39.000
to another path, it might take longer than the Windows operating system is used to waiting.

00:13:39.000 --> 00:13:44.000
And so it'll all of a sudden think that disk is down and start reporting the disk is down

00:13:44.000 --> 00:13:45.000
and, you know, things like that.

00:13:45.000 --> 00:13:49.000
So you want to increase that value so that way the Windows VM will be a little bit more

00:13:49.000 --> 00:13:52.000
patient in case of a path failover.

00:13:52.000 --> 00:13:53.000
All right?

00:13:53.000 --> 00:13:58.000
So with LUNs, GIGSXI hosts are compatible with LUNs.

00:13:58.000 --> 00:14:01.000
Of course, it can use LUNs on the storage array.

00:14:02.000 --> 00:14:06.000
All LUNs need the appropriate HPA before the connection.

00:14:06.000 --> 00:14:08.000
So you just need to have your HPAs configured.

00:14:08.000 --> 00:14:10.000
You need the HPAs on the host.

00:14:10.000 --> 00:14:15.000
You can't configure a host to use a data store, a LUN to configure a data store, until all

00:14:15.000 --> 00:14:16.000
the HPAs are configured and things like that.

00:14:16.000 --> 00:14:21.000
It's like saying you can't connect to a disk until you've installed the SCSI adapter, of course, right?

00:14:21.000 --> 00:14:22.000
LUNs can be shared between hosts.

00:14:22.000 --> 00:14:25.000
That's one thing that's really interesting is that I can have a LUN.

00:14:25.000 --> 00:14:27.000
I format it with VMFS.

00:14:28.000 --> 00:14:33.000
And in a Windows environment, typically, only one server is using that at a time, right?

00:14:33.000 --> 00:14:36.000
There are these multi-active and things like that, but it gets a little bit unstable and

00:14:36.000 --> 00:14:37.000
stuff like that.

00:14:37.000 --> 00:14:40.000
Not all people usually want to use that.

00:14:40.000 --> 00:14:48.000
But in a vSphere environment, I can have seven or eight hosts connected to one data store,

00:14:48.000 --> 00:14:51.000
right, or one LUN using different VMs on there.

00:14:51.000 --> 00:14:55.000
And they're reading and writing from that one file system all at the same time.

00:14:55.000 --> 00:14:59.000
Multiple hosts are reading and writing from that file system all at the same time.

00:14:59.000 --> 00:15:02.000
It's pretty fascinating how well VMware's done that.

00:15:02.000 --> 00:15:06.000
And they've done it really well for, like, a couple of decades.

00:15:06.000 --> 00:15:09.000
It's pretty impressive.

00:15:09.000 --> 00:15:10.000
So, vMotion or DRS.

00:15:10.000 --> 00:15:17.000
So, vMotion is a way where I can have a VM running on one host and then move it live

00:15:17.000 --> 00:15:20.000
without bringing the VM down to another host.

00:15:21.000 --> 00:15:27.000
And I can do that because the VM lives on a LUN on a SAN that both hosts can see, right?

00:15:27.000 --> 00:15:33.000
If that VM isn't on a data store that both hosts can see at the same time, then I can't

00:15:33.000 --> 00:15:34.000
do that vMotion.

00:15:34.000 --> 00:15:38.000
I can do a storage vMotion and a vMotion at the same time, which is I change the storage

00:15:38.000 --> 00:15:42.000
and the compute at the same time, but that's a different conversation.

00:15:42.000 --> 00:15:45.000
DRS is the same thing.

00:15:45.000 --> 00:15:48.000
So, basically, DRS is just automated vMotions.

00:15:48.000 --> 00:15:52.000
It's where the system looks at all the hosts and says, this host here is getting really,

00:15:52.000 --> 00:15:53.000
really busy.

00:15:53.000 --> 00:15:56.000
Its CPU is going at, like, 90%.

00:15:56.000 --> 00:15:59.000
And this host over here is only going at 20%.

00:15:59.000 --> 00:16:00.000
This one's only going at 30%.

00:16:00.000 --> 00:16:04.000
Let's move some of the VMs from this host to these other two and even that CPU utilization

00:16:04.000 --> 00:16:05.000
out.

00:16:05.000 --> 00:16:07.000
And I'm using CPU as an example, right?

00:16:07.000 --> 00:16:09.000
So, vMotion is around.

00:16:09.000 --> 00:16:14.000
Again, in order to do that, in order to have things like vMotion so DRS can work, we need

00:16:14.000 --> 00:16:17.000
to have that shared storage, okay?

00:16:17.000 --> 00:16:22.000
And in order to have that all happen and all work, the data storage needs to look the same

00:16:22.000 --> 00:16:23.000
to all those hosts.

00:16:23.000 --> 00:16:27.000
So, meaning it needs to have the same LUN ID and the same worldwide names and things

00:16:27.000 --> 00:16:30.000
like that.

00:16:30.000 --> 00:16:31.000
Implementing a Fibre Channel SAM.

00:16:31.000 --> 00:16:34.000
So, in order to do Fibre Channel, you have to have an HPA.

00:16:34.000 --> 00:16:39.000
With iSCSI, you don't, because with iSCSI, you can use a software initiator with Fibre

00:16:39.000 --> 00:16:40.000
Channel over Ethernet.

00:16:40.000 --> 00:16:46.000
I don't, but I can use a Fibre Channel over Ethernet software initiator as well.

00:16:46.000 --> 00:16:50.000
But to do a true Fibre Channel SAM, you need to have an HPA.

00:16:50.000 --> 00:16:51.000
You want the HPAs.

00:16:51.000 --> 00:16:56.000
It's best if all the HPAs are in a cluster, are from the same vendor and the same firmware

00:16:56.000 --> 00:16:58.000
and they're all patched the same.

00:16:58.000 --> 00:17:01.000
You don't want a mixture of HPA vendors.

00:17:01.000 --> 00:17:05.000
You don't want a mixture of firmware versions because that can make the performance seem

00:17:05.000 --> 00:17:09.000
inconsistent to you.

00:17:09.000 --> 00:17:10.000
So, Secure Boot.

00:17:10.000 --> 00:17:11.000
What is Secure Boot?

00:17:11.000 --> 00:17:17.000
Basically, Secure Boot is a way where we can specify that we want the image that we're

00:17:17.000 --> 00:17:22.000
booting from to be provided by a trusted vendor, right?

00:17:22.000 --> 00:17:27.000
So, the operating system that I'm booting up will have basically an encrypted file that

00:17:27.000 --> 00:17:30.000
shows that it's a trusted source, right?

00:17:30.000 --> 00:17:35.000
We don't want to make sure that you've got changed and all of a sudden now there's a

00:17:35.000 --> 00:17:40.000
hacker's changed part of my kernel and I've got a root kit, right, and something weird

00:17:40.000 --> 00:17:41.000
has happened to my network.

00:17:41.000 --> 00:17:45.000
It'll be encrypted and the certificate that I'm using to boot from will be able to decrypt

00:17:45.000 --> 00:17:48.000
that and I'll be able to say, oh, yeah, that is what I'm looking for.

00:17:48.000 --> 00:17:51.000
My hash will come out correctly, basically.

00:17:51.000 --> 00:17:52.000
All right.

00:17:52.000 --> 00:17:55.000
So, it's basically saying that all the software that I'm using to boot my operating system

00:17:55.000 --> 00:18:00.000
is signed by a trusted certificate for this, right?

00:18:00.000 --> 00:18:02.000
What do you need for Secure Boot?

00:18:02.000 --> 00:18:07.000
You need an EFI firmware in your motherboard, virtual hardware version 13 or later if you're

00:18:08.000 --> 00:18:12.000
doing Secure Boot with the virtual machines and the OS that supports Secure Boot, which

00:18:12.000 --> 00:18:16.000
Linux systems do, Windows systems do, pretty much all modern operating systems we'll be

00:18:16.000 --> 00:18:19.000
using do.

00:18:19.000 --> 00:18:20.000
And then we have Fiber Channel SAN.

00:18:20.000 --> 00:18:24.000
This is kind of walking through a process we kind of already talked about.

00:18:24.000 --> 00:18:29.000
So, it's going to be – configuring the SAN itself is going to be specific to the vendor,

00:18:29.000 --> 00:18:30.000
right?

00:18:30.000 --> 00:18:31.000
You're going to connect the host to the SAN.

00:18:31.000 --> 00:18:33.000
How are we connecting the host to the SAN?

00:18:34.000 --> 00:18:38.000
Either through some kind of a switch, Fiber Channel switch, or Ethernet switch, or we

00:18:38.000 --> 00:18:43.000
can connect directly from the host into a Fiber Channel SAN.

00:18:43.000 --> 00:18:46.000
I've actually seen iSCSI implementations done that way, too.

00:18:46.000 --> 00:18:48.000
I don't recommend that for iSCSI, but you can do it.

00:18:48.000 --> 00:18:50.000
I've seen it done quite a few times.

00:18:50.000 --> 00:18:52.000
Configure the HBA on the connected host.

00:18:52.000 --> 00:18:56.000
So, when you're talking about configuring the HBA, if it's a software initiator, we're

00:18:56.000 --> 00:18:59.000
going to associate a VM kernel port with it.

00:18:59.000 --> 00:19:04.000
If it's a physical HBA, we might need to do some configuration on the HBA itself to point

00:19:04.000 --> 00:19:08.000
it towards the SAN for, like, booting and things like that if we're doing a LUN boot.

00:19:08.000 --> 00:19:12.000
Ensure the hosts have iSCSI installed, obviously, right?

00:19:12.000 --> 00:19:16.000
Spin up the VMs with the guest OS if we're going to be doing any kind of VMs running

00:19:16.000 --> 00:19:17.000
at a certain time.

00:19:17.000 --> 00:19:19.000
And the VM has access to the SAN.

00:19:19.000 --> 00:19:22.000
The VM itself doesn't really have access to the SAN.

00:19:22.000 --> 00:19:26.000
It has access to its virtual disks that live on the SAN.

00:19:29.000 --> 00:19:31.000
So, booting from a Fiber Channel SAN.

00:19:31.000 --> 00:19:38.000
We're actually able to boot our ESXi host, which I kind of alluded to, from a LUN on a SAN,

00:19:38.000 --> 00:19:40.000
for example, a Fiber Channel SAN.

00:19:40.000 --> 00:19:42.000
In order to do that, you have to have an HBA.

00:19:42.000 --> 00:19:44.000
So, that's why most often it would be Fiber Channel.

00:19:44.000 --> 00:19:47.000
If you have an iSCSI HBA, they can do this also.

00:19:47.000 --> 00:19:52.000
If you're using a software initiator, you can't do a boot from LUN.

00:19:52.000 --> 00:19:57.000
So, boot from LUN, we're going to configure, obviously, on the SAN.

00:19:57.000 --> 00:19:59.000
We're going to configure the SAN with a LUN.

00:19:59.000 --> 00:20:03.000
The LUN is going to be allowed access from an HBA.

00:20:03.000 --> 00:20:10.000
And normally, you're going to want to only allow access from a specific single HBA because it's for one host.

00:20:10.000 --> 00:20:13.000
Then we're going to go to the HBA, and we're going to point the HBA,

00:20:13.000 --> 00:20:16.000
we're going to log into it and tell it that we're going to use it as a boot device,

00:20:16.000 --> 00:20:18.000
and this is the LUN.

00:20:18.000 --> 00:20:19.000
This is the SAN.

00:20:19.000 --> 00:20:21.000
This is the LUN we're going to boot from.

00:20:21.000 --> 00:20:27.000
Then we need to go into our BIOS and tell our BIOS that our boot device is going to be our Fiber Channel HBA,

00:20:27.000 --> 00:20:30.000
and then it will show the LUN that we're going to be booting from on there.

00:20:30.000 --> 00:20:34.000
Then you can go in and you can boot up, and when you go to install your operating system,

00:20:34.000 --> 00:20:40.000
your HBA will be an adapter that you can use, and the LUN will be a disk that you can use.

00:20:40.000 --> 00:20:46.000
When you go to install eSXI, if you have an HBA in there running and you've already presented storage to it,

00:20:46.000 --> 00:20:50.000
it's going to show you all the different LUNs that are on there.

00:20:50.000 --> 00:20:53.000
Even if they're not configured as boot devices, it will show you all the LUNs it can see,

00:20:53.000 --> 00:20:56.000
because those are disks that the installer can see.

00:20:56.000 --> 00:21:02.000
And if that LUN happens to be running production virtual machines, it can format it and wipe them out.

00:21:02.000 --> 00:21:11.000
So usually if you're not doing a boot from LUN, you want to not plug in your HBA cables during that installation process

00:21:11.000 --> 00:21:13.000
or be really, really careful.

00:21:13.000 --> 00:21:17.000
Make sure you're choosing a local disk and you're booting to the right local disk.

00:21:18.000 --> 00:21:20.000
Make sure you're choosing the correct LUN.

00:21:20.000 --> 00:21:24.000
And usually it's going to be a really small LUN compared to the ones that you have VM drain on.

00:21:24.000 --> 00:21:30.000
So if you see a LUN that's like 8 terabytes and you see a LUN that's a couple hundred gigs or something,

00:21:30.000 --> 00:21:31.000
it's probably that small LUN, right?

00:21:31.000 --> 00:21:36.000
So make sure you're choosing the right one because you don't want to wipe out all the VMs on the LUN

00:21:36.000 --> 00:21:39.000
just trying to install your operating system if you chose the wrong one.

00:21:39.000 --> 00:21:44.000
So choose the right one, install your operating system.

00:21:44.000 --> 00:21:46.000
Configuring HBA to boot.

00:21:46.000 --> 00:21:53.000
So if you have an Emulex HBA, you can configure that to do a boot from SAN.

00:21:53.000 --> 00:21:57.000
That run.lputil, that is a Linux utility.

00:21:57.000 --> 00:22:01.000
And because ESXi is based on Linux and it has a bash shell,

00:22:01.000 --> 00:22:08.000
you should be able to run this utility from your ESXi host to allow you to configure the firmware on your Emulex HBA

00:22:08.000 --> 00:22:10.000
to do its boot from SAN, right?

00:22:10.000 --> 00:22:13.000
You can update the BIOS on there and do your boots from SAN on there.

00:22:13.000 --> 00:22:19.000
Then you need to go to the host and you need to configure the host to boot, like I mentioned before,

00:22:19.000 --> 00:22:21.000
from that HBA and from that LUN.

00:22:21.000 --> 00:22:25.000
You'll need to enable all that in the BIOS after you've configured the HBA itself.

00:22:28.000 --> 00:22:37.000
So once you've done that, you've already gone into the BIOS you chose to boot from that particular device.

00:22:37.000 --> 00:22:40.000
You can say what LUN you're going to start from, all that kind of stuff.

00:22:40.000 --> 00:22:43.000
The worldwide name of the boot device you're going to be using.

00:22:43.000 --> 00:22:44.000
Reboot.

00:22:44.000 --> 00:22:47.000
And you can go in there and you can install your OS.

00:22:49.000 --> 00:22:51.000
So Fiber Channel over Ethernet.

00:22:53.000 --> 00:22:58.000
Basically, there's Fiber Channel frames that are encapsulated in Ethernet frames, right?

00:22:58.000 --> 00:23:00.000
So they're going to be encapsulated to get over your Ethernet network.

00:23:00.000 --> 00:23:03.000
It requires a Fiber Channel over Ethernet adapter.

00:23:03.000 --> 00:23:04.000
It can be a hardware adapter.

00:23:04.000 --> 00:23:06.000
It can be a software adapter.

00:23:07.000 --> 00:23:11.000
A maximum of four ports per host for Fiber Channel over Ethernet.

00:23:11.000 --> 00:23:22.000
Now, if you're using NICs, you can do ones that support FCOE offloading or you can do ones that have no FCOE offloading,

00:23:22.000 --> 00:23:27.000
which means there's regular Ethernet NICs, which means you're using your ISCSI software initiator.

00:23:27.000 --> 00:23:33.000
Okay, you're going to configure a VM kernel port to work with your software initiator.

00:23:33.000 --> 00:23:38.000
And then in vSphere, you're going to go into your storage tab and you're going to add the software adapter.

00:23:38.000 --> 00:23:41.000
You're going to configure the kernel port and all that kind of stuff there.

00:23:41.000 --> 00:23:49.000
And then you need to choose a VM NIC, which means you're going to be choosing basically a VM kernel that you configured to work with that adapter.

00:23:53.000 --> 00:23:59.000
So an ISCSI SAN works a lot like a Fiber Channel over Ethernet software adapter.

00:23:59.000 --> 00:24:03.000
So if you're using ISCSI software adapter, it works kind of the same way.

00:24:03.000 --> 00:24:09.000
If you have a hardware ISCSI HBA, then it works like a Fiber Channel HBA, very similar.

00:24:09.000 --> 00:24:13.000
Not everyone can connect directly to a SAN.

00:24:13.000 --> 00:24:22.000
So advantages of a SAN over the Internet, meaning over an IP, right, not actually the capital I Internet,

00:24:22.000 --> 00:24:28.000
basically is that it's a cheaper way of connecting to a SAN, whereas Fiber Channel traditionally requires expensive HBAs

00:24:29.000 --> 00:24:32.000
and it requires expensive Fiber Channel switching.

00:24:32.000 --> 00:24:34.000
Fiber itself can be more expensive, things like that.

00:24:34.000 --> 00:24:37.000
The SANs are oftentimes a little more expensive.

00:24:37.000 --> 00:24:42.000
This allows you to connect using regular Ethernet adapters, which are less expensive.

00:24:42.000 --> 00:24:47.000
You probably want to get some higher-end adapters still, but they'll be less expensive than a Fiber Channel HBA.

00:24:47.000 --> 00:24:49.000
And you can use the copper you already have.

00:24:49.000 --> 00:24:51.000
Hopefully it's at least 10-gig copper.

00:24:51.000 --> 00:24:56.000
And your Ethernet switches, which hopefully, again, are at least 10-gig at the very least.

00:24:56.000 --> 00:25:00.000
Nowadays, 25-gig is really, really common.

00:25:00.000 --> 00:25:08.000
And it allows you to use that initiator and a VM kernel port to connect to your storage.

00:25:08.000 --> 00:25:16.000
So to configure ISCSI, again, for the storage array itself, it's going to be specific to the vendor, how you set it all up.

00:25:16.000 --> 00:25:21.000
But there are certain things that are going to be the same for everybody, right?

00:25:21.000 --> 00:25:23.000
You're going to configure your storage targets, right?

00:25:23.000 --> 00:25:28.000
You're going to go in there and you can configure, you know, again, you're going to pull your disk.

00:25:28.000 --> 00:25:30.000
You're going to create a LUN, and then you're going to create your storage targets.

00:25:30.000 --> 00:25:33.000
And a lot of times, you can create a group, right?

00:25:33.000 --> 00:25:35.000
They call it a host group.

00:25:35.000 --> 00:25:38.000
So the host is going to be which machine they allow to connect to it.

00:25:39.000 --> 00:25:47.000
It can either be an IP address or it can be this unique worldwide name or actually the UUID ISCSI that you're going to get, right?

00:25:47.000 --> 00:25:55.000
And you can get this from the host, and then you can put it into your storage array and say that anything from this host is allowed to connect to.

00:25:55.000 --> 00:25:57.000
And you can say what LUNs.

00:25:57.000 --> 00:26:01.000
You can say to everything or to this LUN and this LUN or whatever you want to do, right?

00:26:01.000 --> 00:26:05.000
You might configure a diagnostics partition.

00:26:06.000 --> 00:26:11.000
You know, you can use local storage on the host for this or the storage array for that.

00:26:11.000 --> 00:26:14.000
Set a large enough queue for the ISCSI controller driver.

00:26:14.000 --> 00:26:22.000
So, again, this queue depth thing is something that default normally is just 32, but you can go in there and you can adjust it.

00:26:22.000 --> 00:26:31.000
By lowering it down, you can sort of make it so that the VMs get kind of more fair access.

00:26:31.000 --> 00:26:38.000
The problem with that, though, could also be that you could start choking the VMs because the queue could fill up too fast by making them a smaller number.

00:26:38.000 --> 00:26:43.000
A way around that is to enable storage IO control, if you have that with your license,

00:26:43.000 --> 00:26:50.000
because that will dynamically change that queue depth to up to its max by default most of the time until there's contention.

00:26:50.000 --> 00:26:54.000
Then you can start changing that queue depth as needed, all right?

00:26:54.000 --> 00:26:57.000
No support for ISCSI tape drives.

00:26:57.000 --> 00:27:03.000
Multipathing the IO load balancing on a single – to a single physical LUN, right?

00:27:03.000 --> 00:27:07.000
So, IO load balancing would go to multiple LUNs because it's IP-based, right?

00:27:07.000 --> 00:27:09.000
It's not like Fibre Channel.

00:27:09.000 --> 00:27:12.000
It's a little bit different because it's IP-based.

00:27:12.000 --> 00:27:17.000
Multipathing with third-party hardware adapters and with the software or dependent hardware.

00:27:18.000 --> 00:27:25.000
Usually, the multipathing, the third-party multipathing is from the storage array vendor, not from the adapter vendor.

00:27:25.000 --> 00:27:30.000
And you want to make sure that whatever multipathing you're using is supported by ESXi.

00:27:30.000 --> 00:27:36.000
So, you want something that's, like, certified by VMware to work with ESXi, not some unsigned adapter.

00:27:36.000 --> 00:27:44.000
And eight, you'd have to go in through a bunch of hoops to even be able to install an unsigned, you know, VIV or driver onto a host.

00:27:44.000 --> 00:27:47.000
So, that should be not much of a problem anymore.

00:27:47.000 --> 00:27:50.000
Configure the ISCSI adapters and create your ISCSI storage.

00:27:50.000 --> 00:27:58.000
So, we'll show you how to go in there and create data stores on ISCSI storage.

00:27:58.000 --> 00:28:02.000
Once you've set up your ISCSI storage, you're going to configure your ISCSI adapter.

00:28:02.000 --> 00:28:08.000
You can use either a hardware adapter, which does not require a dedicated VM kernel port, or the software,

00:28:08.000 --> 00:28:13.000
which does require a dedicated VMware kernel port, and I'll show you that.

00:28:13.000 --> 00:28:15.000
You're going to create the kernel adapter.

00:28:15.000 --> 00:28:20.000
That's what you have to do before you assign it to the software initiator, obviously.

00:28:20.000 --> 00:28:23.000
You can create the ISCSI adapter, which just simply means you're going to install it.

00:28:23.000 --> 00:28:28.000
You're going to go in there and select software adapters and choose ISCSI software adapter and install it in there.

00:28:28.000 --> 00:28:31.000
And then you're going to attach the VM kernel port to the software adapter.

00:28:31.000 --> 00:28:39.000
Then, once you've done that, you'll run a scan, and the scan should show you what devices, which means what LUNs, it's discovered.

00:28:39.000 --> 00:28:44.000
And then, from there, you can choose to format them to create a VMFS data store.

00:28:44.000 --> 00:28:52.000
So, this is a storage with a hardware HBA.

00:28:52.000 --> 00:28:56.000
Again, you don't need a dedicated VM kernel port for that.

00:28:56.000 --> 00:29:02.000
It's software-dependent hardware, VMware ISCSI adapters.

00:29:03.000 --> 00:29:09.000
So, what they're talking about, basically, is you want to make sure you get devices when you're using these hardware adapters.

00:29:09.000 --> 00:29:14.000
They're supported by VMware, but you're not going to have to dedicate a VM kernel port to them, right?

00:29:14.000 --> 00:29:19.000
But you will need – obviously, you'd have IP installed, which is installed by default.

00:29:19.000 --> 00:29:21.000
No problem there.

00:29:21.000 --> 00:29:25.000
VM kernel adapter, create ISCSI adapter, and then bind the SCSI adapters, okay?

00:29:25.000 --> 00:29:27.000
So, then you're going to create your data store.

00:29:28.000 --> 00:29:38.000
When we get into the lab, I'll walk you through how to actually find your software ISCSI adapter, how to get your kernel adapter to it, how to do a scan, how to find your data store.

00:29:38.000 --> 00:29:41.000
We'll walk through all that.

00:29:41.000 --> 00:29:47.000
So, booting from an ISCSI SAN, it's the same thing, basically, as for a fiber channel.

00:29:47.000 --> 00:29:51.000
You need an HBA, right?

00:29:51.000 --> 00:29:53.000
You're going to get your HBA.

00:29:53.000 --> 00:29:57.000
You're going to configure the HBA menu, and you're going to configure it to be a boot device.

00:29:57.000 --> 00:30:02.000
You're going to save what port on the HBA you want to use for your booting.

00:30:02.000 --> 00:30:04.000
You're going to set an IP address.

00:30:04.000 --> 00:30:15.000
Now, normally, you're going to set the IP address for your ISCSI in ESXi, but because we want to boot, it needs to have an address it can use to boot up.

00:30:15.000 --> 00:30:18.000
So, you're going to go ahead and give it an IP address, set a gateway.

00:30:18.000 --> 00:30:20.000
Hopefully, you're not going through a router.

00:30:20.000 --> 00:30:24.000
Hopefully, a gateway is not really required because you're not going through a router for this.

00:30:24.000 --> 00:30:30.000
But you can set the IP address, NAS gateway, normal IP properties.

00:30:30.000 --> 00:30:42.000
Set the ISCSI name because you're going to want to give that name to the storage array so you can say that this unique name is allowed to connect to this LUN because that's what you're going to be booting from.

00:30:42.000 --> 00:30:49.000
So, all that needs to be done on the initiator in advance in order to boot up and connect and find the LUN over the network, okay?

00:30:49.000 --> 00:30:56.000
And if you're going to use CHAP for, you know, any kind of security, then you can configure CHAP.

00:30:56.000 --> 00:31:02.000
CHAP is so old and insecure, it's kind of up to you if you want to enable it or not.

00:31:02.000 --> 00:31:05.000
So, then you're going to the ISCSI boot parameters.

00:31:05.000 --> 00:31:08.000
So, basically, what that means is you're going to go into the BIOS.

00:31:08.000 --> 00:31:11.000
You're going to choose the adapter.

00:31:11.000 --> 00:31:14.000
You're going to set the IP target and what you want to boot to, right?

00:31:14.000 --> 00:31:16.000
Set the LUN and the ISCSI name.

00:31:16.000 --> 00:31:19.000
Set it as the primary boot device in BIOS.

00:31:19.000 --> 00:31:27.000
And then set what LUN is going to be the target for this boot.

00:31:27.000 --> 00:31:32.000
VMS data store per LUN, obviously, you only want one VMS data store per LUN.

00:31:32.000 --> 00:31:40.000
You don't want multiple data stores on a single LUN, especially if you're trying to boot from it because if you're trying to boot from it, it has to be one because then it wouldn't know what data store.

00:31:40.000 --> 00:31:41.000
Because all it sees is the LUN.

00:31:41.000 --> 00:31:44.000
You don't give the partition ID, it won't know what it's trying to boot from.

00:31:45.000 --> 00:31:46.000
There's multiple on there.

00:31:46.000 --> 00:31:50.000
You might try to boot from the wrong one.

00:31:50.000 --> 00:31:54.000
Someday, your SAN and your ISCSI deployment is going to fail.

00:31:54.000 --> 00:31:56.000
It's an absolute guaranteed.

00:31:56.000 --> 00:31:57.000
They always do.

00:31:57.000 --> 00:31:58.000
And not just ISCSI.

00:31:58.000 --> 00:32:00.000
You know, Fiber Channel fails, too.

00:32:00.000 --> 00:32:01.000
HBAs fail.

00:32:01.000 --> 00:32:03.000
Switches fail.

00:32:03.000 --> 00:32:04.000
Storage controllers fail.

00:32:04.000 --> 00:32:10.000
Storage controllers, especially from your more high-end, reputable storage vendors, are kind of bulletproof.

00:32:10.000 --> 00:32:16.000
I mean, they last forever, but there's failures sometimes, too, right, especially on the older ones as they age.

00:32:16.000 --> 00:32:19.000
So, have a plan.

00:32:19.000 --> 00:32:20.000
What's going to happen?

00:32:20.000 --> 00:32:24.000
So, one of the common things is like, okay, so here's the nice thing about doing a boot from LUN.

00:32:24.000 --> 00:32:25.000
I have this server.

00:32:25.000 --> 00:32:27.000
Maybe it's a blade, right?

00:32:27.000 --> 00:32:28.000
Maybe it's a rack-mount server.

00:32:28.000 --> 00:32:32.000
And the server fails.

00:32:32.000 --> 00:32:34.000
The CPU on the server fails.

00:32:34.000 --> 00:32:36.000
The adapter on the server fails.

00:32:36.000 --> 00:32:37.000
Whatever it is.

00:32:38.000 --> 00:32:41.000
But I have another blade that's like my hot spare.

00:32:41.000 --> 00:32:53.000
I can go in to this other server, whether it be a blade or rack-mount, and I can do all that same configuration I did before, going into the HBA, giving it the IP address, giving it the same name.

00:32:53.000 --> 00:32:56.000
I can, you know, point it to the storage array.

00:32:56.000 --> 00:33:03.000
I can point it to that LUN, go into BIOS, point it to the adapter, point it to the LUN, get it all set up.

00:33:03.000 --> 00:33:09.000
And then when I boot it up, it's going to go to that same LUN that the old one was pointing to, and that host is back.

00:33:09.000 --> 00:33:14.000
That exact same host with that same operating system is back on that server.

00:33:14.000 --> 00:33:26.000
So, it does make recovering from a failure easy if the failure is not on the SAM side, if it's on the server side, because I can easily just point another server to it and get it back.

00:33:26.000 --> 00:33:35.000
So, if you do have hot spares laying around, which on some big enterprise environments, that's more common, that makes it really super easy to recover from.

00:33:35.000 --> 00:33:41.000
So, things are going to fail, know they're going to fail, plan for them to fail, and what are you going to do when they fail?

00:33:41.000 --> 00:33:46.000
And it makes it easy because you can have a plan that says, here's all the settings for each of the hosts.

00:33:46.000 --> 00:33:50.000
If this one fails, just load it on that one over there, and you can bring it right back up again.

00:33:50.000 --> 00:33:52.000
Okay?

00:33:52.000 --> 00:33:54.000
So, some ISCSI best practices.

00:33:54.000 --> 00:33:56.000
How are you monitoring your SAM?

00:33:56.000 --> 00:33:59.000
So, monitor the traffic where it's headed.

00:33:59.000 --> 00:34:01.000
So, two things.

00:34:01.000 --> 00:34:07.000
One, you want to monitor your IP traffic in general and make sure that it's going to the host you want it to go to, right?

00:34:07.000 --> 00:34:11.000
You don't want some rogue system on there trying to, you know, get into your network.

00:34:11.000 --> 00:34:20.000
If your security is set up correctly, if your configurations are set up securely and correctly on your SAM, there shouldn't be rogue hosts being able to see anything anyway.

00:34:20.000 --> 00:34:23.000
But just to make sure, you also want to monitor that traffic.

00:34:23.000 --> 00:34:27.000
You also want to monitor the health of the SAM itself.

00:34:27.000 --> 00:34:31.000
You want to monitor for things like, you know, storage controller errors.

00:34:31.000 --> 00:34:38.000
You know, if something's getting too hot, you know, alarms or heat and things like that, you want to, you know, monitor all that kind of stuff.

00:34:38.000 --> 00:34:42.000
Changing a LUN ID that's attached to the VMFS datastore, things are going to fail.

00:34:42.000 --> 00:34:44.000
Things are going to go down.

00:34:44.000 --> 00:34:46.000
VMs are going to fail.

00:34:46.000 --> 00:34:52.000
If you have, you know, those LUNs attached to some kind of RAID group on something, that RAID group is going to fail.

00:34:52.000 --> 00:35:03.000
If you change a LUN ID, if for some reason you have to change a LUN ID on a system that's working, you need to turn everything off that's on it, make that change,

00:35:03.000 --> 00:35:08.000
and then reconfigure the host that points that datastore again, and then start up the VMs again.

00:35:08.000 --> 00:35:09.000
All right?

00:35:09.000 --> 00:35:12.000
You basically don't want to change LUN IDs, okay?

00:35:12.000 --> 00:35:18.000
iSCSI adapter names need to have a unique worldwide name, okay?

00:35:18.000 --> 00:35:20.000
It needs to be unique worldwide.

00:35:20.000 --> 00:35:22.000
That's why I call it a unique worldwide name.

00:35:22.000 --> 00:35:24.000
Basically, that's just saying, yeah.

00:35:24.000 --> 00:35:31.000
So if you really want to come to the big deal is if you're using a software initiator because you can name it whatever you want.

00:35:31.000 --> 00:35:41.000
And so make sure what you're naming it is going to be really, truly unique in your environment and for anything it might ever, ever see.

00:35:41.000 --> 00:35:42.000
NFS datastore.

00:35:42.000 --> 00:35:44.000
So NFS is great.

00:35:44.000 --> 00:35:47.000
It wasn't always supported at all.

00:35:47.000 --> 00:35:50.000
And then when it was supported, it wasn't supported for production.

00:35:50.000 --> 00:35:53.000
It was really only for, like, templates and ISOs and things like that.

00:35:53.000 --> 00:35:56.000
But over the years, it got better and better.

00:35:56.000 --> 00:35:59.000
And the support for it, VMware support for it got better.

00:35:59.000 --> 00:36:04.000
And NFS itself got faster and faster and more reliable.

00:36:04.000 --> 00:36:07.000
NetApp had a lot to do with that, but not only NetApp.

00:36:08.000 --> 00:36:12.000
And so now NFS is supported for running production workloads on there.

00:36:12.000 --> 00:36:18.000
And even Microsoft supports running production workloads on, you know, ESXi on NFS storage.

00:36:18.000 --> 00:36:26.000
So if you are using it, you need to have your TCPIP stack, you know, correctly set up.

00:36:26.000 --> 00:36:28.000
You want secured somehow.

00:36:28.000 --> 00:36:33.000
You know, choose what security mechanisms you want to use for authenticating against that.

00:36:33.000 --> 00:36:36.000
You don't want to authenticate normally as root.

00:36:36.000 --> 00:36:38.000
You want another account set up.

00:36:38.000 --> 00:36:43.000
But you can also, if you are using root, there's going to be an option on the NFS device.

00:36:43.000 --> 00:36:44.000
It's called NoRootSquash.

00:36:44.000 --> 00:36:47.000
You want to make sure you have NoRootSquash configured on there.

00:36:47.000 --> 00:36:48.000
What can you store?

00:36:48.000 --> 00:36:51.000
VMs, ISOs, templates, pretty much everything.

00:36:51.000 --> 00:36:54.000
You know, production running live VMs.

00:36:54.000 --> 00:37:02.000
Supported features, DRS, HA, vMotion, everything is supported on NFS now with ESXi.

00:37:02.000 --> 00:37:04.000
And it works really well.

00:37:04.000 --> 00:37:05.000
It works really well.

00:37:05.000 --> 00:37:08.000
So this pretty much concludes attaching the network storage.

00:37:08.000 --> 00:37:12.000
Let's go ahead and go to our demo environment, and I'll show you how to configure an iSCSI software adapter.

00:37:12.000 --> 00:37:15.000
So here we are back in our vSphere environment.

00:37:15.000 --> 00:37:18.000
So I'm going to go ahead and choose my host.

00:37:18.000 --> 00:37:21.000
And I'm going to go to Configure.

00:37:21.000 --> 00:37:25.000
And Storage Adapters is the very top one.

00:37:25.000 --> 00:37:29.000
And you can see right here I have an iSCSI software adapter.

00:37:29.000 --> 00:37:32.000
So I can select my software adapter.

00:37:32.000 --> 00:37:37.000
And here are some of the basic properties that are in here that are already configured.

00:37:37.000 --> 00:37:42.000
One thing that you'll want to do that you'll need to do, you know, kind of first if you want to use this,

00:37:42.000 --> 00:37:44.000
is you would have to configure.

00:37:44.000 --> 00:37:48.000
I'm going to jump over here to my VM kernel adapters real quick.

00:37:48.000 --> 00:37:54.000
And I have configured a VM kernel interface just for my iSCSI traffic.

00:37:54.000 --> 00:38:03.000
And as a best practice, what you normally will want to do is you might want to have a separate virtual switch configured.

00:38:03.000 --> 00:38:07.000
With adapters, usually you'll have more than one in a production environment,

00:38:07.000 --> 00:38:12.000
but you'll have adapters dedicated just to your iSCSI storage.

00:38:12.000 --> 00:38:17.000
And they'll create a VM kernel port that is configured to use those adapters, all right?

00:38:17.000 --> 00:38:26.000
So you might have on here some 25-gig adapters that are connected to your storage network that are going to connect to your iSCSI SAN.

00:38:26.000 --> 00:38:35.000
So then back under Storage Adapters here, you can go to Network Bindings, and you'll have your iSCSI adapter selected here.

00:38:35.000 --> 00:38:38.000
Now, because of this virtual environment, I actually have a virtual SAN,

00:38:38.000 --> 00:38:41.000
and so I actually need to use my management network to connect to that.

00:38:41.000 --> 00:38:47.000
But in a production environment, you actually would have your VM kernel adapter connected to that

00:38:47.000 --> 00:38:54.000
and your VM kernel adapter connected to, again, like your 25-gig NICs that are dedicated just to storage.

00:38:54.000 --> 00:39:01.000
If you need to add, you can go to Add, and you can choose the adapter that you need that to connect to,

00:39:01.000 --> 00:39:05.000
and just say OK, and then it would show up over here.

00:39:05.000 --> 00:39:11.000
So really, configuring the software adapter is pretty simple, right?

00:39:11.000 --> 00:39:21.000
The big thing is, again, configuring the virtual switch, attaching the correct adapters to it,

00:39:21.000 --> 00:39:28.000
creating that VM kernel port that has an IP address that's on your iSCSI network, right,

00:39:28.000 --> 00:39:34.000
then assigning that storage adapter a VM kernel port.

00:39:34.000 --> 00:39:43.000
Then once you've done that, you can go in and you can tell it if you want to rescan your storage,

00:39:43.000 --> 00:39:47.000
looking for new storage devices.

00:39:47.000 --> 00:39:50.000
Well, actually, I did skip a step.

00:39:50.000 --> 00:39:55.000
Before you did that, you probably are going to want to go in and set up the discovery.

00:39:55.000 --> 00:40:03.000
You're going to need to go in here and tell it the name or the IP address of your storage array, right?

00:40:03.000 --> 00:40:22.000
So here, you can see what services you have enabled on there, what settings you have set up on there.

00:40:22.000 --> 00:40:29.000
If you want to add a new adapter, you just simply go in, give it the IP address of the storage array,

00:40:30.000 --> 00:40:31.000
and you can tell it what port number.

00:40:31.000 --> 00:40:37.000
3260 is kind of the default for iSCSI, but you can go in there and set a port number,

00:40:37.000 --> 00:40:39.000
but you need to do something different.

00:40:39.000 --> 00:40:45.000
So then once you've added the iSCSI server, right, you've added a VM kernel port,

00:40:45.000 --> 00:40:49.000
you set up the server to be, you know, accessible.

00:40:49.000 --> 00:40:51.000
You know what server you want to connect to.

00:40:51.000 --> 00:40:57.000
On the storage array side, we've already told it the information about the host connecting to it, right,

00:40:57.000 --> 00:40:58.000
and presented a lens to it.

00:40:58.000 --> 00:41:03.000
So we're going to, you know, set the discovery to the VM kernel port.

00:41:03.000 --> 00:41:11.000
Then we're going to say we want to rescan our storage.

00:41:11.000 --> 00:41:12.000
That's running.

00:41:12.000 --> 00:41:14.000
It's going to complete pretty quick.

00:41:14.000 --> 00:41:18.000
While it's running, I can actually go ahead and, because it's already done this before,

00:41:18.000 --> 00:41:36.000
I then go to devices, and this is the storage device that I configured on my storage array to be presented to my VM kernel,

00:41:36.000 --> 00:41:39.000
right, to my software SCSI initiator.

00:41:39.000 --> 00:41:44.000
So from here, I could go in and I can use this to create a new data store,

00:41:44.000 --> 00:41:48.000
we will actually go in and we'll create a data store, create a couple different data stores.