3.5.1
Warning and Error Messages
If warning/error messages are available they are displayed for each hard disk.
The following options are possible:
•
No problems have been found.
(no errors on the hard disk)
•
Please try to repair the errors on this harddisk under Maintenance -> Recovery HD.
•
This HD is not reliable any more. Please replace it as soon as possible.
For detailed information about the errors HISTA messages are displayed (error message F7406):
F7406 M4 N0353 NO ACT A1 DRIVE IO ERROR 13-06-20 16:37:53
ALARM CLASS:CENTRAL:029
FORMAT:33
HD EVENT: smart NodeA SNr:5VG03305 Dev:/dev/sdb Mod:ST9250410AS
ID:5
Val:16
Warning: nonzero
**********************************************************************
F7406 M4 N0354 NO ACT A1 DRIVE IO ERROR 13-06-20 16:38:00
ALARM CLASS:CENTRAL:029
FORMAT:33
HD EVENT: smart NodeA SNr:5VG03305 Dev:/dev/sdb Mod:ST9250410AS
ID:190
Val:31
Warning: failed in the past
**********************************************************************
F7406 M4 N0355 NO ACT A1 DRIVE IO ERROR 13-06-20 16:38:08
ALARM CLASS:CENTRAL:029
FORMAT:33
HD EVENT: smart NodeA SNr:5VG03305 Dev:/dev/sdb Mod:ST9250410AS
ID:197
Val:2
Error: nonzero
**********************************************************************
F7406 M4 N0356 NO ACT A1 DRIVE IO ERROR 13-06-20 16:38:15
ALARM CLASS:CENTRAL:029
FORMAT:33
HD EVENT: smart NodeA SNr:5VG03305 Dev:/dev/sdb Mod:ST9250410AS
ID:198
Val:2
Error: nonzero
NOTE:
ID 197 and ID 198 lead to bad blocks.