9.10 Messages from the DLMgetras utility for collecting HDLM error information

KAPL10001-W


No parameter has been specified.

Details
No parameter (folder to which collected information is output) has been specified.

Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras utility, see 8.2 DLMgetras (utility for collecting HDLM error information).

KAPL10002-W


Too many parameters have been specified.

Details
Four or more parameters have been specified.

Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras utility, see 8.2 DLMgetras (utility for collecting HDLM error information).

KAPL10003-W


The first parameter has not been set to a directory. Value = aa...aa

Details
The first parameter must be set to a folder to which collected information is output.
aa...aa: First parameter

Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras utility, see 8.2 DLMgetras (utility for collecting HDLM error information).

KAPL10004-W


The parameter contains an incorrect value. Value = aa...aa

Details
The first parameter must be a directory.
aa...aa: Invalid parameter

Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras utility, see 8.2 DLMgetras (utility for collecting HDLM error information).

KAPL10009-W


The specified directory already exists. Do you want to overwrite it? [y/n]:

Details
The specified folder already exists. Enter y to overwrite it or n to cancel.

Action
The specified folder already exists. Enter y to overwrite the existing file. Enter n or press any other key to terminate the DLMgetras utility for collecting HDLM error information, without executing it. For details on the DLMgetras utility, see 8.2 DLMgetras (utility for collecting HDLM error information).

KAPL10012-W


The specified file or directory does not exist. Line = aa...aa, Value = bb...bb

Details
The specified file or folder does not exist in the file for defining the information to be collected.
aa...aa: Line number of the file for defining information to be collected (decimal number)
bb...bb: Indicated contents in a line

Action
After the DLMgetras utility for collecting HDLM error information terminates, check the contents of the file for defining the information to be collected. This file is shown in the message. If the contents of the file are incorrect, correct them and then try to collect error information again. The DLMgetras utility will ignore the specified file or directory and continue processing. For details on the DLMgetras utility, see 8.2 DLMgetras (utility for collecting HDLM error information).

KAPL10017-W


You lack privileges for executing the utility for collecting HDLM error information.

Details
The DLMgetras utility for collecting HDLM error information must be executed by a user included in the Administrator group.

Action
Re-execute as a user with Administrator group.privileges. For details on the DLMgetras utility, see 8.2 DLMgetras (utility for collecting HDLM error information).

KAPL10020-I


The file has been obtained successfully. File = aa...aa, Collection time = bb...bb(GMT:bb...bb)

Details
The file to be collected has been obtained.
aa...aa: Collected file name
bb...bb: The year of grace/month/day hour:minute:second

Action
None.

KAPL10022-I


The utility for collecting HDLM error information completed normally.

Details
Error information has been collected.

Action
None. For details on the DLMgetras utility, see 8.2 DLMgetras (utility for collecting HDLM error information).

KAPL10030-I


A user terminated the utility for collecting HDLM error information.

Details
Processing of the DLMgetras utility has been terminated because n was sent as a confirmation reply.

Action
None. For details on the DLMgetras utility, see 8.2 DLMgetras (utility for collecting HDLM error information).

KAPL10031-W


The entered value is invalid. Continue operation ? [y/n]:

Details
A value other than y or n has been entered for a [y/n] request. Enter y or n.

Action
Enter y or n.

KAPL10032-W


The entered value is invalid. The utility for collecting HDLM error information stops.

Details
Processing of the DLMgetras utility for collecting HDLM error information will terminate because an invalid response was sent three times to a request.

Action
Re-execute the DLMgetras utility. For details on the DLMgetras utility, see 8.2 DLMgetras (utility for collecting HDLM error information).

KAPL10033-W


The file does not exist. Filename = aa...aa

Details
The file subject to collection does not exist.
aa...aa: File subject to collection

Action
This file is normally obtainable, so the environment might be invalid. Check the system configuration.

KAPL10034-E


The file could not be copied. Filename = aa...aa, Details = bb...bb

Details
Execution of the cp command failed.
aa...aa: File name you tried to copy
bb...bb: cp output message

Action
An error occurred while the file to be collected was being copied. The user environment might have been unstable. Check the system configuration.

KAPL10041-I


Collection of aa...aa information will now start.

Details
aa...aa: Log information to be collected

Action
None.

KAPL10042-I


Collection of aa...aa information will now finish.

Details
aa...aa: Collected log information

Action
None.

KAPL10043-I


Error information is being collected. (aa...aa%)

Details
aa...aa: Collected log information as a percentage of all information to be collected

Action
None.

KAPL10044-W


There is insufficient disk space.

Details
DLMgetras utility for collecting HDLM error information execution will now stop because the available disk space has decreased to less than 50 MB.

Action
Re-execute in an environment that has at least 50 MB of free disk space.

KAPL10045-W


A parameter is invalid.

Details
The specified parameter is invalid.

Action
Make sure that the parameters for the DLMgetras utility for collecting HDLM error information are appropriate, and then try again.

KAPL10046-W


A parameter value is invalid.

Details
The specified parameter is invalid.

Action
Make sure that the parameters for the DLMgetras utility for collecting HDLM error information are appropriate, and then try again.

KAPL10047-W


A necessary parameter value has not been specified. (parameter = aa...aa)

Details
A mandatory parameter value has not been specified.
aa...aa: Parameter name

Action
Make sure that the parameters for the DLMgetras utility for collecting HDLM error information are appropriate, and then try again.

KAPL10048-E


An error occurred in internal processing of the utility for collecting HDLM error information. Details = aa...aa, bb...bb

Action
Contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.

KAPL10080-I


Data for maintenance: aa...aa bb...bb cc...cc dd...dd

Details
aa...aa: Maintenance information
bb...bb: Error number of the Windows API (hexadecimal number)
cc...cc and dd...dd: Fixed to 0 (hexadecimal number)

Action
None

KAPL10081-I


Data for maintenance: aa...aa bb...bb cc...cc dd...dd

Details
aa...aa: Maintenance information
bb...bb: Error number of the Windows API (hexadecimal number)
cc...cc and dd...dd: Fixed to 0 (hexadecimal number)
ee...ee: The command that could not be executed, and the registry key that could not be obtained.

Action
None