5.2.4 Configuration view in the view frame

The view frame of the Path Management window displays one of the following two views:

This subsection explains the window components in the Configuration view. Depending on the connected storage subsystem, some items might not be displayed.

The following figure shows a display example of the Configuration view.

Figure 5-4 Display example of the Configuration view

[Figure]

The top part of the Configuration view shows a configuration example for the host. The bottom part shows a configuration example for the storage subsystem.

The following figure shows a configuration example for the host in the Configuration view.

Figure 5-5 Configuration example for the host in the Configuration view

[Figure]

The following figure shows a configuration example for the storage subsystem in the Configuration view.

Figure 5-6 Configuration example for the storage subsystem in the Configuration view

[Figure]

When using the Hitachi USP, the display format for the following items is different from that for other storage subsystems:

The following figure shows a configuration example for the storage subsystem when Hitachi USP is used.

Figure 5-7 Configuration example for the storage subsystem in the Configuration view (for Hitachi USP)

[Figure]

The Configuration view is displayed only when you use one of the storage subsystems below. The view frame displays a message if the Configuration view is not displayed.

Also, the following buttons and check boxes for the Configuration view are not displayed:

The following describes each window component:

Type:
In Type: you can select the type of path to be displayed in the view frame. The selectable types are Owner path and Non-owner path.
The display changes as follows depending on the path to be applied when you use load balancing in your storage subsystem.
  • When owner paths or non-owner paths exist:
    By default, both the Owner path and Non-owner path check boxes are selected.
    The Type: specification has priority over the Status: specification. For example, if you select only the Owner path option in Type: , the Configuration view will display only the owner paths whose statuses are selected in the Status: check boxes.
    When you clear the Owner path check box or Non-owner path check box, the Configuration view narrows down the displayed paths accordingly.
    Note that the Type: settings remain in effect even when you click the Path List tab and switch to the Path List view.
    Owner path check box
    When you select Owner path, the Configuration view displays owner paths.
    Non-owner path check box
    When you select Non-owner path, the Configuration view displays non-owner paths.
  • When all paths are owner paths:
    In Type: you can select the type of path to be displayed in the Configuration view. Since all paths are owner paths, only the Owner path check box is displayed as active.
    The Type: specification has priority over the Status: specification. For example, if you clear the Owner path check box in Type:, the Configuration view will not display those paths even if their statuses are selected in the Status: check boxes.
    Note that the Type: settings of the Configuration view remain in effect even when you click the Path List tab and switch to the Path List view.
    Owner Path check box
    Select Owner path to display owner paths. Clear Owner path to hide all paths.
    For details on the paths to which load balancing is applied, see the HDLM manual.

Status:
You use the following four check boxes to select the status of the paths to be displayed. By default, all check boxes are selected.
When you clear a Status: check box, the Configuration view narrows down the items displayed.
  • [Figure] Online path check box
    When you select this check box, the Configuration view displays the paths that have the Online or Online(P) status.
  • [Figure] Offline path check box
    When you select this check box, the Configuration view displays the paths that have the Offline(C) status.
  • [Figure] Offline (Error) path check box
    When you select this check box, the Configuration view displays the paths that have the Offline(E) or Offline(P) status.
  • [Figure] Online (Error) path check box
    When you select this check box, the Configuration view displays the paths that have the Online(E) or Online(EP) status.
Note that the Status: settings remain in effect even when you click the Path List tab and switch to the Path List view.

Online button
Clicking this button changes the status of a selected path (or paths) to Online.
When no path is displayed in the Configuration view, or all the paths displayed in the Configuration view are in the Online status and no path is selected, the Online button is displayed as inactive.
If you click this button without first selecting a path, the Configuration view changes the status of all paths that are not already Online to Online.
If you attempt to change the status of multiple paths to Online but the status of one of those paths cannot be changed, a message appears. To ignore the path whose status cannot be changed and to continue processing, click the OK button. To stop processing, click the Cancel button.

Offline button
Clicking this button changes the status of a selected path (or paths) to Offline(C).
In a cluster configuration, if a user selects a path whose status is Online and clicks the Offline button during reserve processing, the status of the selected path switches to Online(P), which indicates that the offline processing is in a waiting-to-execute state. Despite this change in status, however, the appearance of the line that indicates the path status does not change. After the reserve processing finishes and the offline processing executes, the path status will switch to Offline(C); however, the path information displayed in the Configuration view will not be automatically updated. To display the most recent path status, click the Refresh button.
When no path is displayed in the Configuration view, or no path is selected, the Offline button is displayed as inactive.
If you attempt to change the status of multiple paths to Offline(C) but one of those paths cannot be changed, a message appears. To ignore the path whose status cannot be changed and to continue processing, click the OK button. To stop processing, click the Cancel button.

Host
host is displayed.

HBA port button
Displays the HBA port number as the host port number (hexadecimal) converted into decimal.
The HBA ports that are actually connected are usually displayed as active. If, however, the Type: or Status: check box specifies that a connected path is not to be displayed, the HBA port button is displayed as inactive.
Placing the mouse pointer over an HBA port button displays a tool tip containing the HBA port number.
Clicking an HBA port button displayed as active selects all the paths connected to that clicked HBA port.

Note
The paths are not displayed in the Configuration view when they are connected to an HBA port whose HBA port number is 16 or higher. To view or operate these paths, use the Path List view. For details about the Path List view, see 5.2.3 Path List view in the view frame.

Paths
The paths that meet the conditions selected in the Type: and Status: check boxes are displayed. Lines are used to indicate the paths connecting a host and storage subsystem. Table 5-5 Appearance of lines that indicate paths, and the path status shows the appearance of lines that indicate paths, and the corresponding path status.
Placing the mouse pointer over a path displays a tool tip giving the path status (Online, Offline(C), Offline(E), Offline(E) (intermittent error), Online(E), or Online(E) (intermittent error)) and whether the path is an owner path or non-owner path.
When you click any of the following window components and select a path, the line is displayed thicker than before:
  • Line that indicates a path
  • HBA port button
  • CHA port button
  • CHA button

    Table 5-5 Appearance of lines that indicate paths, and the path status

    Lines that indicate paths Path status
    [Figure] (Black unbroken line) Online or Online(P)
    [Figure] (Black broken line) Offline(C)
    [Figure] (Red broken line)# Offline(E) or Offline(P)
    [Figure] (Red unbroken line)# Online(E) or Online(EP)
    When the LU dynamic deletion functionality is used, the path whose status is Online(E) is deleted. Therefore it is not displayed.

    #
    If the intermittent error monitoring functionality is enabled, the line that indicates the error path flashes when an intermittent error occurs in the path.

  • When using Hitachi USP
    When you display the CHA port in the minimized mode, one of the paths that has the most impact on the system is displayed when multiple paths connect to the CHA. The displayed paths are sorted in the following order of path status values:
    1. Online(E) (intermittent error)
    2. Online(E) or Online(EP)
    3. Offline(E) (intermittent error)
    4. Offline(E) or Offline(P)
    5. Offline(C)
    6. Online or Online(P)

CHA port button
These buttons display the CHA port number.
The buttons for the channel adapter ports that are actually connected are usually displayed as active. If, however, the Type: or Status: check box specifies that a connected path is not to be displayed, the CHA port button is displayed as inactive.
Clicking a button displayed as active selects all the paths connected to that clicked channel adapter port.
For some storage subsystems, placing the mouse pointer over a CHA port button displays a tool tip containing the CHA port number.
When the Expand button or Minimize button is displayed, the CHA port button is displayed in the minimized or expanded mode for each CHA. When you click the Minimize button or Expand button, you can change the mode by which the CHA ports are displayed.
The following explains the displays in the minimized mode and expanded mode.
  • Display in the minimized mode
    All the CHA ports belonging to a CHA are integrated and displayed as one label. The button displays the first CHA port number and the last CHA port number, connected by a hyphen (-).
    If the connected paths are disabled by selecting the Type: or Status: check boxes, the CHA port button will also be disabled.
    You cannot select a path by clicking an active CHA port button.
  • Display in the expanded mode
    Each CHA port belonging to a CHA is displayed in a button independently.
    If the connected paths are disabled by selecting the Type: or Status: check boxes, the corresponding CHA port button will also be disabled.
    Clicking an active button selects all paths connected to the selected CHA port button.

Expand button and Minimize button
The buttons switch the mode for displaying the CHA ports of each CHA. Depending on the connected storage subsystem, the buttons might not be displayed.
  • Expand button ([Figure])
    The Expand button appears when the CHA ports are displayed in the minimized mode. When you click this button, it changes to the Minimize button and all the CHA port numbers belonging to the selected CHA appears. When you place the mouse pointer on the Expand button, Expand is displayed in the tool tip.
  • Minimize button ([Figure])
    The Minimize button appears when the CHA ports are displayed in the expanded mode. When you click this button, it changes to the Expand button and one CHA port number that integrates all the CHA ports belonging to the selected CHA appears.
    When you place the mouse pointer on the Minimize button, Minimize is displayed in the tool tip.
When there is already a CHA port in the expanded mode and you switch another CHA port to the expanded mode, the first CHA port in the expanded mode is switched to the minimized mode. Only one CHA can be in the expanded mode.
The Expand or Minimize button is always active, whether or not the path connected to the CHA is displayed.

CHA button
This button indicates a channel adapter.
When neither the Expand button nor the Minimized button is displayed, the CHA button is displayed as follows:
  • When one or more CHA ports belonging to a CHA are active, the corresponding CHA buttons become active.
  • Depending on the connected storage subsystem type, the button indicates whether the path connected to the CHA is an owner path or a non-owner path based on the information about the path connected to the LU. Also, if you selected a storage subsystem in the tree frame, owner paths and non-owner paths are not distinguished.
  • When you click an active button, all the paths connected to the ports belonging to the clicked CHA are selected.
    For storage subsystems in which owner paths and non-owner paths are not distinguished, a CHA number is not displayed.
When the Expand button or Minimize button is displayed, the CHA button is displayed as follows:
  • A CHA number is displayed because the cluster and the CHA are distinguished. The button shows a character string consisting of CHA and CHA-number connected by a hyphen.
  • When one or more CHA ports belonging to a CHA are active, the CHA buttons become active. When you click the CHA button, all the paths connected to the ports belonging to the clicked CHA are selected.

CL 1
This area displays the cluster number (CL 1) of the RAID device.

CL 2
This area displays the cluster number (CL 2) of the RAID device.

LU
If you selected a storage subsystem in the tree frame, the box next to LU displays the number of LUs that can be accessed from the host and storage subsystem.
If you selected an LU in the tree frame, the box next to LU displays the LU number.

Subsystem
This box displays the name of the storage subsystem that you selected in the tree frame. A storage subsystem name consists of the following three elements, separated by periods:
  • Vendor ID: the name of the storage subsystem vendor
  • Model ID: indicates the model name of the storage subsystem
  • Serial number: the serial number of the storage subsystem